<Selection method of general-purpose magnetic flux vector control>
Mitsubishi standard
SF-JR
motor
SF-HR
Mitsubishi high
Others
efficiency motor
SF-JRCA 4P
Mitsubishi constant-
SF-HRCA 4P
torque motor
Others (SF-JRC, etc.)
Other manufacturer's
standard motor
Other manufacturer's
constant-torque
motor
∗1
Refer to page 111, for other settings of Pr. 71.
∗2
Refer to page 113 for offline auto tuning.
Set the motor capacity and the number of motor poles.
(Pr. 80, Pr. 81) (Refer to page 76)
Select the control method.(Pr. 800) (Refer to page 76)
Set the operation command. (Refer to page 183)
As required
Perform offline auto tuning. (Pr. 96) (Refer to page 113)
Set slip compensation. (Pr. 245, Pr. 246, Pr. 247) (Refer to page 84)
NOTE
Uneven rotation slightly increases as compared to the V/F control. (It is not suitable for machines such as grinding
machine and wrapping machine which requires less uneven rotation at low speed.
When a surge voltage suppression filter (FR-ASF-H/FR-BMF-H) is connected between the inverter and motor, output
torque may decrease.)
Parameters referred to
Pr.3 Base frequency, Pr.19 Base frequency voltage
Pr.71 Applied motor
Pr.77 Parameter write selection
Adjust the output torque of the motor (current)
Perform secure wiring.
(Refer to page 14)
Set the motor.(Pr. 71)
Motor
Set motor capacity (kW) in Pr. 80 Motor capacity and
the number of motor poles (number of poles) in Pr. 81 Number of motor poles.
(V/F control is performed when the setting is "9999" (initial value).
Set "30" in Pr. 800 to make general-purpose magnetic flux vector control valid.
Select the start command and speed command.
(1)Start command
1)Operation panel: Setting by pressing
2)External command: Setting by forward rotation or reverse rotation
command (terminal STF or STR)
(2)Speed command
1)Operation panel: Setting by pressing
2)External analog command (terminal 2 or 4):
Give a speed command using the analog signal input to terminal 2 (or
terminal 4).
3)Multi-speed command:
The external signals (RH, RM, RL) may also be used to give speed
command.
Test run
Refer to page 91
Refer to page 111
Refer to page 179
Pr. 71 Setting ∗1
0 (initial value)
40
3
Offline auto tuning is necessary.
1
50
13
Offline auto tuning is necessary.
3
Offline auto tuning is necessary.
13
Offline auto tuning is necessary.
Remarks
∗2
∗2
∗2
∗2
of the operation panel
of the operation panel
83