Mitsubishi Electric FR-E720-600 Instruction Manual page 100

Hide thumbs Also See for FR-E720-600:
Table of Contents

Advertisement

Frequency setting by external terminals
(2) Jog operation from PU
Selects JOG operation mode from the operation panel and PU (FR-PU04/FR-PU07). Operation is performed only while
the start button is pressed.
Operation
1.
Confirmation of the RUN indication and
operation mode indication
The monitor mode should have been
selected.
The inverter should be at a stop.
2.
Press
to choose the PU JOG operation
mode.
3.
Press
.
While
is pressed, the motor rotates.
The motor runs at 5Hz. (Pr. 15 initial value)
4.
Release
[When changing the frequency of PU JOG operation]
5.
Press
to choose the parameter setting
mode.
6.
Turn
until Pr. 15 JOG frequency appears.
7.
Press
to show the currently set value.
(5Hz)
8.
Turn
to set the value to "
(10Hz)
9.
Press
to set.
10.
Perform the operations in steps 1 to 4.
The motor rotates at 10Hz.
98
R/L1
Three-phase AC
S/L2
power supply
T/L3
Operation panel
Hold down.
Release
".
Flicker...Parameter setting complete!!
Inverter
U
V
Motor
W
PRM indication is lit.
(The parameter number read previously
appears.)
Display
Stop

Advertisement

Table of Contents
loading

Table of Contents