2.3.3

Wiring of control circuit

(1)
Standard control circuit terminal layout
Terminal screw size
M3: (Terminal A, B, C)
M2: (Other than the above)
(2)
Wiring method
1) Strip off the sheath of the cable of the control circuit to wire.
Strip off the sheath about the size below. If the length of the sheath pealed is too long, a short circuit may occur among
neighboring wires. If the length is too short, wires might come off.
Cable stripping size
Introduced products on bar terminals
Terminal Screw Size
M3 (terminal A, B, C)
M2 (other than the above)
Bar terminal crimping tool: CRIMPFOX ZA3 (Phoenix Contact Co., Ltd.)
2) Loosen the terminal screw and insert the cable into the terminal.
3) Tighten the screw to the specified torque.
Undertightening can cause cable disconnection or malfunction. Overtightening can cause a short circuit or malfunction
due to damage to the screw or unit.
Tightening torque: 0.5N·m to 0.6N·m (terminal A, B, C)
0.22N·m to 0.25N·m (other than the above)
* Screwdriver:
Small flat-blade screwdriver (Tip thickness: 0.4mm/tip width: 2.5mm)
(3)
Control circuit common terminals (SD, 5, SE)
Terminals SD, SE and 5 are common terminals for I/O signals.(All common terminals are isolated from each other.) Do not
earth them. Avoid connecting the terminal SD and 5 and the terminal SE and 5.
Terminal SD is a common terminal for the contact input terminals (STF, STR, RH, RM, RL, MRS, RES). The open collector
circuit is isolated from the internal control circuit by photocoupler
Terminal 5 is a common terminal for the frequency setting signals (terminals 2 or 4) and analog signal output (AM). It should
be protected from external noise using a shielded or twisted cable.
Terminal SE is a common terminal for the open collector output terminal (RUN, FU). The contact input circuit is isolated from
the internal control circuit by photocoupler
10
2
5
A
B
Wire the stripped cable after twisting it to prevent it
from becoming loose. In addition, do not solder it.
Use a bar terminal as necessary.
L
Terminal A, B, C
Other than the above
2
Wire Size (mm
)
With Insulation Sleeve
0.3 to 0.5
Al 0,5-6WH
0.5 to 0.75
Al 0,75-6GY
0.3 to 0.5
Al 0,5-6WH
Control circuit specifications
4 RUN FU SE
AM
RL
RM
RH
MRS
RES
SD
C
L(mm)
6
5
Bar Terminal Model
Without Insulation Sleeve
A 0,5-6
A 0,75-6
A 0,5-6
PC
STF STR
SD
SD
Maker
Phoenix Contact
Co.,Ltd.
2
25