Fujitsu ApeosPrint C4030 Reference Manual page 121

Table of Contents

Advertisement

10.
Tap on [Print Sample] > [Print].
The sample copy reflecting the adjustment value you entered is printed.
[Lead/Side Registration] Adjustment
1.
Tap on [Lead/Side Registration].
2.
Enter the value obtained by adding the adjustment amount to the current setting (1 step = 0.1
mm).
Note
[Lead Registration (L)]
Adjustment amount (mm) = 10 - A (mm)
[Side Registration (S)]
Adjustment amount (mm) = 10 - B (mm)
Ideal image
10 mm
Actual image
3.
Tap on [OK].
[Clean Developer Unit and Transfer Module]
After the machine has been remained with powered on but not perform printing for a certain period,
the background of the print result may have some unwanted colored parts. To improve this fault,
clean the Developer Unit and the Transfer Module.
10 mm
Sub scan direction
(Paper feed direction)
10 mm
A
10 mm
B
5.7 [Maintenance]