Sign In
Upload
Manuals
Brands
Fujitsu Manuals
Server
PRIMERGY CX2550 M1
Fujitsu PRIMERGY CX2550 M1 Manuals
Manuals and User Guides for Fujitsu PRIMERGY CX2550 M1. We have
2
Fujitsu PRIMERGY CX2550 M1 manuals available for free PDF download: Upgrade And Maintenance Manual, Operating Manual
Fujitsu PRIMERGY CX2550 M1 Upgrade And Maintenance Manual (222 pages)
Brand:
Fujitsu
| Category:
Server
| Size: 4.69 MB
Table of Contents
Copyright and Trademarks
2
Version History
6
Table of Contents
7
1 Introduction
15
Notational Conventions
16
2 Before You Start
17
Classification of Procedures
19
Customer Replaceable Units (CRU)
19
Upgrade and Repair Units (URU)
20
Field Replaceable Units (FRU)
21
Average Task Duration
22
Tools You Need at Hand
23
Documents You Need at Hand
24
Documents for the Server Node
25
Documents for the Server Enclosure
26
3 Important Information
27
Safety Instructions
27
CE Conformity
35
FCC Class a Compliance Statement
36
Environmental Protection
37
4 Basic Hardware Procedures
39
Shutting down the Server Node
39
Removing the Server Node from the Server Enclosure
40
Removing the Riser Module
41
Installing the Riser Module
43
Replacing the Riser Card
45
Mounting a Controller to the Riser Module
46
Removing a Controller from the Riser Module
47
Removing the Memory Slot Air Ducts
48
Installing the Memory Slot Air Ducts
49
Design of the Memory Air Ducts
49
Installing the Server Node in the Server Enclosure
50
Controls and Indicators on the Server Node
51
Concluding Software Tasks
51
5 Basic Software Procedures
53
Starting the Maintenance Task
53
Suspending Bitlocker Functionality
53
Disabling SVOM Boot Watchdog Functionality
54
Viewing Boot Watchdog Settings
54
Configuring Boot Watchdog Settings
55
Configuring LAN Teaming
57
Note on Server Maintenance in a Multipath I/O Environment
57
Switching on the ID Indicator
60
Completing the Maintenance Task
61
Updating or Recovering the System Board BIOS and Irmc
61
Updating or Recovering the System Board BIOS
61
Updating or Recovering the Irmc
65
Verifying System Information Backup / Restore
67
Updating RAID Controller Firmware
67
Enabling Option ROM Scan
68
Resetting the Boot Retry Counter
70
Viewing the Boot Retry Counter
70
Enabling SVOM Boot Watchdog Functionality
72
Enabling Replaced Components in the System BIOS
73
Verifying the Memory Mode
74
Verifying the System Time Settings
75
Viewing and Clearing the System Event Log (SEL)
76
Viewing the SEL
76
Clearing the SEL
77
Updating the NIC Configuration File in a Linux Environment
77
Resuming Bitlocker Functionality
79
Performing a RAID Array Rebuild
80
Looking up Changed MAC / WWN Addresses
80
Looking up MAC Addresses
80
Looking up WWN Addresses
81
Using the Chassis ID Prom Tool
82
Configuring LAN Teaming
82
After Replacing / Upgrading LAN Controllers
83
After Replacing the System Board
83
Switching off the ID Indicator
83
Performing a Fan Test
84
Resetting the Error Status after Replacing Memory Modules or Processors
86
Memory Modules
86
Processors
87
6 Expansion Cards
91
Basic Information
92
Additional Tasks
95
Mounting Expansion Card Slot Brackets
95
General Instructions
95
Network Adapter D2755
96
Handling SFP+ Transceiver Modules
98
Installing SFP+ Transceiver Modules
98
Removing an SFP+ Transceiver Module
103
Replacing SFP+ Transceiver Modules
106
Expansion Cards in the Riser Module
107
Installing Expansion Cards
108
Preliminary Steps
108
Mounting a Controller to the Riser Module
109
Concluding Steps
109
Removing Expansion Cards
110
Preliminary Steps
110
Removing a Controller from the Riser Module
111
Concluding Steps
111
Replacing Expansion Cards
112
Preliminary Steps
112
Removing an Expansion Card
112
Installing an Expansion Card
113
Concluding Steps
113
Riser Card
114
Replacing the Riser Card
114
Preliminary Steps
114
Replacing the Riser Card
115
Concluding Steps
116
7 Main Memory
117
Basic Information
118
Memory Sequence
118
Operation Modes
120
Installing Memory Modules
121
Preliminary Steps
121
Installing a Memory Module
122
Concluding Steps
123
Removing Memory Modules
124
Preliminary Steps
124
Removing a Memory Module
125
Concluding Step
126
Replacing Memory Modules
127
Preliminary Steps
127
Removing a Memory Module
128
Installing a Memory Module
128
Concluding Steps
128
8 Processors
129
Basic Information
130
Supported Processors
130
Processor Locations
130
Replacing Processors
131
Preliminary Steps
131
Removing Processor Heat Sinks
132
Removing the Processor Heat Sinks
132
Removing the Processor
133
Installing the Processor
137
Applying Thermal Paste
140
Installing the Processor Heat Sink
142
Processor Heat Sink CPU1
142
Processor Heat Sink CPU2
142
Installing the Heat Sinks
143
Concluding Steps
144
Replacing the Processor Heat Sink
145
Preliminary Steps
145
Removing the Processor Heat Sink
145
Installing the Processor Heat Sink
145
Concluding Steps
146
9 System Board and Components
147
Replacing the CMOS Battery
147
Preliminary Steps
148
Localization of the CMOS Battery
149
Removing the CMOS Battery
150
Installing the CMOS Battery
151
Concluding Steps
152
Sata Dom
153
Installing the SATA DOM Board
153
Preliminary Steps
153
Installing the SATA DOM
154
Concluding Steps
158
Removing the SATA DOM
159
Preliminary Steps
159
Removing the SATA DOM
160
Concluding Steps
161
Replacing the SATA DOM
162
Preliminary Steps
162
Removing the SATA DOM
162
Re-Installing the SATA DOM
163
Concluding Steps
163
USB Flash Module (UFM)
164
Installing the UFM Board
164
Required Tools
164
Preliminary Steps
164
Installing the UFM Board
165
Concluding Steps
168
Software Configuration
168
Removing the UFM Board
169
Preliminary Steps
169
Removing the UFM Board
170
Concluding Steps
171
Replacing the UFM Board
171
Preliminary Steps
171
Removing the UFM
171
Re-Installing the UFM
172
Concluding Steps
172
Software Configuration
173
Irmc Microsd Card
174
Installing the Irmc Microsd Card
174
Preliminary Steps
174
Installing the Irmc Microsd Card
175
Concluding Steps
175
Removing the Irmc Microsd Card
176
Preliminary Steps
176
Concluding Steps
177
Replacing the Irmc Microsd Card
178
Preliminary Steps
178
Concluding Steps
178
Replacing the System Board
179
Preliminary Steps
180
Replacing the System Board
180
Removing the System Board
181
Installing the System Board
183
Swapping Processors
184
Completing the System Board
185
Concluding Steps
185
10 Liquid Cooling
187
Liquid Cooling Kit for the Server Node
187
Basic Information
187
Main Components of the Server Node
187
Riser Module for the Liquid Cooling Kit
187
Liquid Cooling Kit
188
Replacing the Liquid Cooling Kit
189
Preliminary Steps
189
Removing the Liquid Cooling Kit
189
Installing a Liquid Cooling Kit
192
Concluding Steps
198
Cooling Pads on the Memory Modules
199
Basic Information
199
Adhesive Rules for the Memory Cooling Pads
200
Preparing the Memory Modules
202
Preliminary Steps
202
Preparing a Memory Module
202
Concluding Steps
202
11 Cabling
205
Cabling Overview
206
Cabling
206
Cabling for HDD 2.5
208
Cabling Onboard
208
Cabling with RAID-Controller
209
12 Appendix
211
Mechanical Overview
211
Server Node Interior
211
Server Node Rear
212
Connectors and Indicators
213
Connectors and Indicators on the System Board
213
Onboard Connectors
213
Onboard Settings
215
Connector Panel
217
Controls and Indicators
217
Control Elements
217
Global Error Indicator, ID Indicator, CSS Indicator
218
LAN Indicators
219
Minimum Startup Configuration
220
Advertisement
Fujitsu PRIMERGY CX2550 M1 Operating Manual (54 pages)
Server Node
Brand:
Fujitsu
| Category:
Server
| Size: 0.86 MB
Table of Contents
Copyright and Trademarks
2
Table of Contents
5
1 Introduction
7
Concept and Target Groups for this Manual
7
Documentation Overview
8
Notational Conventions
9
2 Functional Overview
11
Features
11
Server Node Specification
15
3 Installation Steps, Overview
19
4 Important Information
21
Safety Instructions
21
CE Conformity
29
FCC Class a Compliance Statement
30
Transporting the Server Node
31
Environmental Protection
31
5 Hardware Installation
33
Unpacking the Server Node
34
Connecting Devices to the Server Node
35
Notes on Connecting/Disconnecting Cables
37
6 Starting up and Operation
39
Controls and Indicators
39
Controls and Indicators on the Server Node
39
Control Elements
40
Global Error Indicator, ID Indicator, CSS Indicator
40
LAN Indicators
42
Switching the Server Node on and off
43
Configuring the Server Node
46
Configuring the Onboard SATA Controller
46
Configuring the SAS/SATA RAID Controller
46
Operating System Installation
47
Cleaning the Server Node
48
7 Property and Data Protection
49
BIOS Setup Security Functions
49
8 Troubleshooting and Tips
51
Power-On Indicator Remains Unlit
51
Server Node Switches Itself off
51
Screen Remains Blank
52
Flickering Stripes on Monitor Screen
52
No Screen Display or Display Drifts
53
Incorrect Date and Time
54
System will Not Boot
54
Error Message on Screen
54
Advertisement
Related Products
Fujitsu PRIMERGY CX2550 M4
Fujitsu PRIMERGY CX2550 M5
Fujitsu PRIMERGY CX2550 M2
Fujitsu PRIMERGY CX2550 M6
Fujitsu Primergy CX250 S2
Fujitsu PRIMERGY CX2560 M4
Fujitsu PRIMERGY CX2570 M4
Fujitsu PRIMERGY CX25 0 M4 Series
Fujitsu PRIMERGY CX2570 M5
Fujitsu PRIMERGY CX2560 M6
Fujitsu Categories
Air Conditioner
Laptop
Server
Scanner
Storage
More Fujitsu Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL