Miele FNS 7794 E Operating Instructions Manual page 30

Table of Contents

Advertisement

Installation
If the outlet is no longer accessible after
installation, an additional means of dis-
connection must be provided for all
poles. Suitable means of disconnection
include switches with an all-pole dis-
connect device with a contact opening
of at least 1/8" (3 mm). These can be
circuit breakers, fuses, and relays.
The plug and power cord must not
come into contact with the back of the
appliance as vibrations can cause dam-
age to these components. This could
result in a short circuit.
Do not plug other appliances into elec-
trical outlet behind this appliance.
Temporary or permanent operation on
an autonomous power supply system or
a power supply system that is not syn-
chronized with the grid power supply
(e.g., island networks, back-up sys-
tems) is possible. A prerequisite for op-
eration is that the power supply system
complies with the specifications of
EN 50160 or an equivalent standard.
The function and operation of the pro-
tective measures provided in the do-
mestic electrical installation and in this
Miele product must also be maintained
in isolated operation or in operation that
is not synchronized with the grid power
supply, or these measures must be re-
placed by equivalent measures in the
installation.
If the power cord needs to be replaced,
this must be performed by a qualified
technician.
30
Connecting the appliance
 Insert the electrical plug into the back
of the refrigeration appliance.
Make sure that the electrical plug has
clicked into position correctly.
 Insert the electrical plug of the refrig-
eration appliance into the socket.
The refrigeration appliance is now con-
nected to the electricity supply.