A shut-off valve must be provided be-
tween the hose and the plumbed-water
connection to ensure that the water
supply can be cut off if necessary.
Make sure that the shut-off valve is
still accessible after the appliance
has been installed.
Water supply
Ensure that the connections are tight
and leak-proof.
Risk of damage to the hose.
The water supply from the shut-off
valve to the ice-cube maker has
been interrupted.
Do not bend or damage the hose.
A shut-off valve with a metric
R3/4 thread must be incorporated
when connecting to the water supply.
The solenoid valve is located at the
back of the refrigeration appliance on
the bottom right. It also has a metric
R3/4 thread.
– Connecting the hose to the refriger-
ation appliance
Pull the cover off the thread of the so-
lenoid valve.
Position the angled end of the
hose horizontally on the holder
and hold onto it securely.
Screw the nut onto the thread by
hand until it is securely in place.
Installation
27