Mitsubishi Electric FR-D720-0.4K Instruction Manual page 69

Hide thumbs Also See for FR-D720-0.4K:
Table of Contents

Advertisement

Parameter list
Func-
Parameter
Name
tion
80
Motor capacity
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
90
Motor constant (R1)
96
Auto tuning setting/status
117
PU communication station number
118
PU communication speed
119
PU communication stop bit length
120
PU communication parity check
121
Number of PU communication retries
122
PU communication check time interval
123
PU communication waiting time setting
124
PU communication CR/LF selection
Terminal 2 frequency setting gain
125
frequency
Terminal 4 frequency setting gain
126
frequency
PID control automatic switchover
127
frequency
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
145
PU display language selection
146
Built-in potentiometer switching
∗6
150
Output current detection level
Output current detection signal delay
151
time
152
Zero current detection level
153
Zero current detection time
156
Stall prevention operation selection
157
OL signal output timer
160
Extended function display selection
Frequency setting/key lock operation
161
selection
Automatic restart after instantaneous
162
power failure selection
Stall prevention operation level for
165
restart
62
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0.1 to 15kW, 9999
0.01kW
9999
76, 106
0 to 500A, 9999
0.01A
9999
106
200V/400V
0 to 1000V
0.1V
106
∗5
10 to 120Hz
0.01Hz
60Hz
106
0 to 50Ω , 9999
0.001Ω
9999
106
106,
0, 11, 21
1
0
137
182,
0 to 31 (0 to 247)
1
0
199
182,
48, 96, 192, 384
1
192
199
0, 1, 10, 11
1
1
182
182,
0, 1, 2
1
2
199
0 to 10, 9999
1
1
183
183,
0, 0.1 to 999.8s, 9999
0.1s
0
199
0 to 150ms, 9999
1ms
9999
182
0, 1, 2
1
1
182
0 to 400Hz
0.01Hz
60Hz
154
0 to 400Hz
0.01Hz
60Hz
154
0 to 400Hz, 9999
0.01Hz
9999
211
211,
0, 20, 21, 40 to 43
1
0
219
211,
0.1 to 1000%, 9999
0.1%
100%
219
211,
0.1 to 3600s, 9999
0.1s
1s
219
211,
0 to 100%, 9999
0.1%
9999
219
211,
0 to 100%, 9999
0.1%
9999
219
211,
0 to 100%, 9999
0.01%
9999
219
211,
0.01 to 10s, 9999
0.01s
9999
219
0 to 7
1
0
236
0, 1
1
1
241
0 to 200%
0.1%
150%
125
0 to 10s
0.1s
0s
125
0 to 200%
0.1%
5%
125
0 to 1s
0.01s
0.5s
125
0 to 31, 100, 101
1
0
80
0 to 25s, 9999
0.1s
0s
80
0, 9999
1
9999
163
0, 1, 10, 11
1
0
237
0, 1, 10, 11
1
1
137
0 to 200%
0.1%
150%
137
Customer
Parameter
Remarks
Setting
80
82
83
84
90
96
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
145
146
150
151
152
153
156
157
160
161
162
165
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
Copy
V/F
V/F
V/F
GP MFVC
GP MFVC
GP MFVC
×
50
D0
0
×
52
D2
0
×
53
D3
0
×
54
D4
0
5A
DA
0
60
E0
0
11
91
1
12
92
1
13
93
1
14
94
1
15
95
1
16
96
1
17
97
1
18
98
1
19
99
1
1A
9A
1
1B
9B
1
1C
9C
1
1D
9D
1
1E
9E
1
1F
9F
1
20
A0
1
21
A1
1
22
A2
1
2D
AD
1
2E
AE
1
32
B2
1
33
B3
1
34
B4
1
35
B5
1
38
B8
1
39
B9
1
00
80
2
01
81
2
02
82
2
05
85
2
Parameter list
Parameter
Clear
All clear
×
×
×
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
∗8
×
×
×
×
×
×
4
×

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents