Mitsubishi Electric FR-D720-0.4K Instruction Manual page 143

Hide thumbs Also See for FR-D720-0.4K:
Table of Contents

Advertisement

Operation selection at power failure and instantaneous power failure
Execution of tuning
POINT
Before performing tuning, check the monitor display of the operation panel or parameter unit (FR-PU04/FR-PU07) if the
inverter is in the status for tuning. (Refer to 2) below)
1) When performing PU operation, press
For External operation, turn ON the start command (STF signal or STR signal). Tuning starts.
(Excitation noise is produced during tuning.)
NOTE
To force tuning to end, use the MRS or RES signal or press
signal or STR signal) OFF also ends tuning.)
During offline auto tuning, only the following I/O signals are valid: (initial value)
Input terminal <Valid signal> STF, STR
Output terminal RUN, SO, FM, A, B, C
Note that the progress status of offline auto tuning is output in five steps from FM when speed and output frequency
are selected.
Since the RUN signal turns ON when tuning is started, caution is required especially when a sequence which
releases a mechanical brake by the RUN signal has been designed.
When executing offline auto tuning, input the run command after switching ON the main circuit power (R/L1, S/L2, T/
L3) of the inverter.
Do not perform ON/OFF switching of the second function selection signal (RT) during execution of offline auto
tuning. Auto tuning is not executed properly.
When Pr. 79 = "7" (PU operation interlock), turn ON the X12 signal, and tune in the PU operation mode.
2) Monitor is displayed on the operation panel and parameter unit (FR-PU04, FR-PU07) during tuning as below.
Pr. 96 setting
(1) Setting
(2) Tuning in progress
(3) Normal end
(4) Error end
(when inverter protective function
operation is activated)
REMARKS
It takes approximately 9s until tuning is completed.
3) When offline auto tuning ends, press
OFF the start signal (STF signal or STR signal) once.
This operation resets the offline auto tuning and the PU's monitor display returns to the normal indication.
(Without this operation, next operation cannot be started.)
of the operation panel.
Parameter Unit
Operation Panel Indication
(FR-PU04, FR-PU07)
21
READ:List
21
STOP PU
TUNE
22
STF
FWD PU
23
TUNE
COMPLETION
STF
STOP
PU
TUNE
9
ERROR
STOP PU
STF
of the operation panel during PU operation. For External operation, turn
of the operation panel. (Turning the start signal (STF
21
Flickering
4
141