Technical data
EVSE
Standards
Declaration of Conformity
Low voltage Directive
EMC
RED
Additional compliace with standards
Communication to the EV
1. ABB uses AC cables/connectors from suppliers, who also declare compliance with this standard
10.1.2 Technical data table - Terra 360
EVSE
Connector
Charging standard (IEC 61851-1)
Number of outputs
Number of EV served
Output combinations
Cable type
Cable Length
Efficiency
DC Output
DC output power
DC output voltage
DC output current
Overvoltage category
AC Input
Input connection
Input voltage
Input frequency
Input Current
Input power
Power Factor
Harmonic Distortion (THD)
Earthing systems
Overvoltage category
Protection
SPD - According to EN 61643-11 and IEC 61643-11
SPD - Nominal discharge current (8/20 us) [L-N] / [N-PE]
SPD - Short-circuit withstand capability (ISCCR)
Short circuit current
Tilt sensor (option)
Voltage input
Power consumption
Reverse polarity protection
EN 61851-1:2011, EN 61851-23:2014, IEC 61851-
1:2010, IEC 61851-23:2014, EN IEC 61851-1:2019,
EN IEC 61851-21-2:2021, IEC 61851-21-2:2018
V11.1.2:2017, EN IEC 62311:2020, EN 50364:2018
1
DIN 70121, ready for ISO 15118 - 2 Plug'n'Charge
TN-S, TN-C, TN-C-S, TT (with upstream RCD)
Overcurrent, overvoltage, undervoltage, ground
overtemperature, integrated surge protection
Terra 60 CCT
CE
IEC 61851-1:2017
EN 300330 V2.1.1:2017, EN 301908-13
IEC 62196-2, IEC 62196-3
Terra 360 CC
Mode 4
2
Up to two EV in parallel
2x CCS 2 connectors
Air cooled cable
Standard: 4.7 m
> 95% at nominal output power
360kW (peak)
CCS 150...920 VDC
Nominal 300A DC
Peak 500A DC
II
3 Phases + PE
400 Vac +/- 10%
50 Hz
560 A
390KVA
> 0.96 @ full load
4.5% at full output power
III
fault including DC leakage protection,
Yes, Type 2 / Class 2
20 kA / 80 kA
25 kA
25 kA
20...24 V DC
Max 30 mA
Yes