Problem
The tines do not raise.
The tines do not engage the ground.
Possible Cause
1. There is a short in the wire harness.
2. The return-to-up springs are not
properly adjusted.
3. The return-to-up springs are damaged.
1. The tine down pressure setting is too
low.
2. Electronic depth control is set too
shallow.
3. The harness/switch is damaged.
4. The auxiliary reservoir is low on oil.
55
Corrective Action
1. Contact an Authorized Service Dealer.
2. Adjust the return-to-up springs.
3. Replace the return-to-up springs.
1. Increase the tine down pressure.
2. Increase the electrical depth control
setting.
3. Contact an Authorized Service Dealer.
4. Add oil to the reservoir.