Field Data Of Iso Transponders (Mds D) - Siemens SIMATIC Ident RF340R02 System Manual

Table of Contents

Advertisement

Planning the RF300 system
4.2 Field data for transponders, readers and antennas
4.2.2

Field data of ISO transponders (MDS D)

The limit distances (S
transmission window for each reader-transponder combination are listed in the tables below.
Observe the following information for field data of ISO transponders:
● A maximum median deviation of ±2 mm is permitted in static mode (without affecting the
field data).
● In dynamic mode, make sure that rectangular transponders cross the antenna field in the
longitudinal direction.
Table 4- 10
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D423
MDS D424
MDS D425
MDS D426
MDS D428
MDS D460
MDS D524
MDS D525
MDS D526
MDS D528
All values are in mm
56
) and operating distances (S
g
Field data RF310R reader
Length of the transmission
window (L)
40
30
90
105
30
130
120
80
30
85
90
55
35
30
90
30
30
35
30
90
30
) along with the length of the
a
Operating distance (S
)
a
2...93
2...64
2...65
5...96
2...39
2...90
2...80
2...74
2...47
5...74
2...104
2...35
1...68
1...22
5...75
1...40
1...32
1...70
1...22
5...80
1...43
System Manual, 07/2017, C79000-G8976-C345-07
Limit distance (S
)
g
105
72
73
109
44
102
90
83
63
84
115
40
75
25
90
45
38
78
25
90
48
SIMATIC RF300