Siemens SIMATIC Ident RF340R02 System Manual page 91

Table of Contents

Advertisement

Reader RF350R with ANT 30 and with ISO transponders (MDS D)
Table 4- 52
Transponder
MDS D124
MDS D126
MDS D160
MDS D324
MDS D422
MDS D423
MDS D424
MDS D425
MDS D426
MDS D428
MDS D460
MDS D522
SIMATIC RF300
System Manual, 07/2017, C79000-G8976-C345-07
Reduction of field data due to metal, range as %: Transponder and RF350R with ANT 30
Without metal
1)
On metal; distance 15 mm
Flush-mounted in metal;
distance all round 15 mm
Without metal
1)
On metal; distance 25 mm
Flush-mounted in metal;
distance all round 50 mm
Without metal
1)
On metal, distance 10 mm
Without metal
1)
On metal; distance 15 mm
Flush-mounted in metal;
distance all round 25 mm
Without metal
On metal, distance 0 mm
Flush-mounted in metal;
distance all round 0 mm
Without metal
On metal, distance 0 mm
Flush-mounted in metal;
distance all round 0 mm
Without metal
1)
On metal 15 mm
Flush-mounted in metal;
distance all round 25 mm
Without metal
On metal, distance 0 mm
Without metal
1)
On metal; distance 25 mm
Flush-mounted in metal;
distance all round 50 mm
Without metal
On metal, distance 0 mm
Without metal
1)
On metal, distance 10 mm
Without metal
On metal, distance 0 mm
Planning the RF300 system
4.3 Installation guidelines
ANT 30 without metal
100
85
80
100
90
85
100
85
100
90
80
100
95
90
100
125
2)
80
100
95
85
100
95
100
90
80
100
95
100
95
100
95
ANT 30 mounted in met-
al
(20 mm all-round)
85
75
45
85
75
70
80
75
80
70
65
85
85
80
80
115
2)
70
85
85
75
80
80
85
75
70
90
90
90
85
85
85
91

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ident rf300Simatic ident rf310r02

Table of Contents