Planning the RF300 system
4.3 Installation guidelines
With ISO transponders (MDS E)
Table 4- 39
Transponder
MDS E600
MDS E611
MDS E624
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
1)
adequate clearance to the metal.
Transponder flush-mounted in metal; minimum distance to the reader is 5 mm
2)
Transponder flush-mounted in metal; minimum distance to the reader is 15 mm
3)
78
Reduction of field data due to metal, range as %: Transponder and RF340R
Without metal
1)
On metal; distance 20 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
1)
On metal; distance 20 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
1)
On metal; distance 15 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
100
70
60
3)
100
70
60
3)
100
85
80
2)
System Manual, 07/2017, C79000-G8976-C345-07
RF340R reader
On metal
Flush-mounted
in metal
(20 mm all-
round)
90
75
65
60
45
45
90
75
65
60
45
45
95
80
85
75
80
45
SIMATIC RF300