Siemens SIMATIC Ident RF340R02 System Manual page 92

Table of Contents

Advertisement

Planning the RF300 system
4.3 Installation guidelines
Transponder
MDS D524
MDS D525
MDS D526
MDS D528
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
1)
adequate clearance to the metal.
Values of > 100 % can occur if transponders were developed specifically for mounting in/on metal-
2)
lic surroundings.
Reader RF350R with ANT 30 and with ISO transponders (MDS E)
Table 4- 53
Transponder
MDS E624
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
1)
adequate clearance to the metal.
92
Flush-mounted in metal;
distance all round 0 mm
Without metal
1)
On metal 15 mm
Flush-mounted in metal;
distance all round 25 mm
Without metal
On metal, distance 0 mm
Without metal
1)
On metal; distance 25 mm
Flush-mounted in metal;
distance all round 50 mm
Without metal
On metal, distance 0 mm
Reduction of field data due to metal, range as %: Transponder and RF350R with ANT 30
Without metal
1)
On metal; distance 15 mm
Flush-mounted in metal;
distance all round 15 mm
ANT 30 without metal
90
100
95
85
100
95
100
90
80
100
95
ANT 30 without metal
100
85
80
System Manual, 07/2017, C79000-G8976-C345-07
ANT 30 mounted in met-
al
(20 mm all-round)
80
85
85
75
80
80
85
75
70
90
90
ANT 30 mounted in met-
al
(20 mm all-round)
85
75
45
SIMATIC RF300