Siemens SIMATIC Ident RF340R02 System Manual page 104

Table of Contents

Advertisement

Planning the RF300 system
4.4 Chemical resistance of the readers and transponders
4.4.2.4
Polyphenylene sulfide (PPS)
The data memory has special chemical resistance to solutions up to a temperature of 200
°C. A reduction in the mechanical properties has been observed in aqueous solutions of
hydrochloric acid (HCl) and nitric acid (HNO3) at 80 °C. The plastic housings are resistant to
all types of fuel including methanol.
Table 4- 61
Substance
Acetone
n-Butanol (butyl alcohol)
Butanone-2 (methyl ethyl ketone)
n-Butyl acetate
Brake fluid
Calcium chloride (saturated)
Diesel fuel
Diethyl ether
Frigen 113
Anti-freeze
Kerosene
Methanol
Engine oil
Sodium chloride (saturated)
Sodium hydroxide
Sodium hypochlorite
(30 or 180 days)
Sodium hydroxide solution
Nitric acid
Hydrochloric acid
Sulfuric acid
Tested fuels
FAM testing fluid
acc. to DIN 51 604-A
Toluene
1, 1, 1-Trichloroethane
Xylene
Zinc chloride (saturated)
104
Chemical resistance - polyphenylene sulfide (PPS)
Test conditions
Concentration [%]
Temperature [°C]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
30%
5%
5%
30%
10%
10%
10%
10%
30%
-
-
-
-
-
System Manual, 07/2017, C79000-G8976-C345-07
Rating
55 ℃
++++
80 ℃
++++
60 ℃
++++
80 ℃
++++
80 ℃
++++
80 ℃
++++
80 ℃
++++
23 ℃
++++
23 ℃
++++
120 ℃
++++
60 ℃
++++
60 ℃
++++
80 ℃
++++
80 ℃
++++
80 ℃
++++
80 ℃
++
80 ℃
-
90 ℃
++++
23 ℃
++++
80 ℃
-
23 ℃
++++
80 ℃
++
23 ℃
++++
80 ℃
++++
80 ℃
++
80 ℃
++++
80 ℃
++
75 ℃
++++
SIMATIC RF300