Replace An Access Module In An Nvme Expansion Enclosure; Identify A Faulted Access Module From Powerstore Manager; Remove An Access Module - Dell PowerStore 1000 Installation And Service Manual

Table of Contents

Advertisement

Replace an Access Module in an NVMe expansion
enclosure
Take the following actions to remove the faulted Access Module from the NVMe expansion enclosure and install a replacement
Access Module.

Identify a faulted Access Module from PowerStore Manager

Before you replace an Access Module, ensure that you have identified its location within the system. Using PowerStore
Manager, you can identify and locate a faulted Access Module.
Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance that contains the Access Module that you need to replace.
3. On the Components card, under Rear View, expand ExpansionEnclosure.
4. Select the relevant Access Module.
Faulted parts appear in red in the image of the system, and report a status of Faulted in the State field.

Remove an Access Module

About this task
NOTE:
Access Module 1 is on the top of the NVMe expansion enclosure and Access Module 2 is on the bottom.
Steps
1. Label and remove the cables from the Access Module.
2. Press both orange buttons to release the Access Module latches.