GE NEMA User's Manual & Installation Instructions page 52

Evse charging station
Table of Contents

Advertisement

g
EV Charging Station
Technical Characteristics
SAE Compliant
Vehicle Interface
Cable Length
AC Max Charging Power Output**
Voltage and Current Rating
AC Power Input
Short Circuit Rating
Recommended Service Panel
Breaker
Ground Fault Protection
Cold Load Start
Local Area Network
Network Communication Protocol
Network Security
Metering Accuracy
RFID Reader
Display Screen
Standby Power
Indoor Ventilation
Outdoor Rated
Safety Compliance
Surge Protection
EMI Compliance
Operating Temperature
Operating Humidity
Approximate Shipping Weights
Dimensions
**The maximum power consumption is determined by EVSE. The actual power consumption is
determined by EV.
GE EV Charging Station User Manual
User Manual & Installation Instructions
Level II per J1772
SAE J1772 EV connector
20' cable
7.2 kW (240VAC @ 30A)
208-240VAC @ 30A
208-240VAC requiring only Line 1, Line 2 and Earth ground
5kA @ 240 VAC
Pole, Wall, Single Pedestal: 2-pole 40A breaker on dedicated circuit
Double Pedestal: (Qty. 2) 2-pole 40A breaker on dedicated circuit
Internal 20mA CCID with auto-re-closure, does not require a GFCI
in service panel
Random start up between 0 and 15 minutes
CAT5 Ethernet
TCP/IP
GE recommends that network be VPN and Firewall protected
2% accurate on voltage and current; 4% accurate on power and
energy
ISO15693 compliant
Vacuum Fluorescent Display
5W typ.
Signal provided to turn on facility fans
Enclosure NEMA 3R
UL 2231, UL 2251, UL 2594, cUL 2231, cUL 2594, NEC 625, SAE
J1772
6kV @ 3000A
FCC Part 15 Class A
-30C to +50C ambient
Up to 95% non-condensing
Single Pedestal: 120 lb
Single Pedestal: 160 lb
Pole: 75 lb
Wall: 75 lb
Single Pedestal: 57.6"H x 18.4"W x 20.9"D
Double Pedestal: 57.6"H x 18.4"W x 28"D
Wall: 31.5"H x 14.9"W x 11.2"D
Pole: 31.5"H x 14.9"W x 11.2"D
- Table 10 -
52 of 86