F u n c .
N a m e
C o d e
C144
Logic output 1 operator
Logic output 2 operand A
C145
Logic output 2 operand B
C146
Logic output 2 operator
C147
C148
Logic output 3 operand A
C149
Logic output 3 operand B
Logic output 3 operator
C150
C160
Input [1] response time
C161
Input [2] response time
Input [3] response time
C162
Input [4] response time
C163
Input [5] response time
C164
C165
Input [6] response time
C166
Input [7] response time
Multistage speed/position
C169
determination time
C900
IRDY action selection
C901
Processing cycle of
overload advance notice
signal select (Ver.3.1 or
after)
C902
Filter time constant for
overload advance notice
signal (Ver.3.1 or after)
Overload advance notice
C903
signal hysteresis (Ver.3.1
or after)
" C " F u n c t i o n
D e s c r i p t i o n
Applies a logic function to calculate
[LOG] output state,
Three options:
00[LOG] = A AND B
01[LOG] = A OR B
02[LOG] = A XOR B
All the programmable functions
available for logic (discrete) outputs
except LOG1 to LOG3, OPO, no
Applies a logic function to calculate
[LOG] output state,
Three options:
00[LOG] = A AND B
01[LOG] = A OR B
02[LOG] = A XOR B
All the programmable functions
available for logic (discrete) outputs
except LOG1 to LOG3, OPO, no
Applies a logic function to calculate
[LOG] output state,
Three options:
00[LOG] = A AND B
01[LOG] = A OR B
02[LOG] = A XOR B
Sets response time of each input
terminal, set range:
0 (x 2 [ms]) to 200 (x 2 [ms])
(0 to 400 [ms])
Set range is 0. to 200. (x 10ms)
00 Before Ver. 3.0
01 Ver. 3.0 and after
If you set"01:Ver. 3.0 and after",
"GS1 and GS2 Both Close
(operation possible side)" is added
to condition of IRDY turning ON as
"Logical product".
0040 msec.
012 msec.
It effects detection of output current
that is used for judgement of
overload advance notice signal,
range is 0 to 9999 ms.
The ratio for the rated current of
each INV mode. It effects turning
off of overload advance notice
signal,
range is 00.00 to 50.00 %
73
D e f a u l ts
Run
Mode
I n i t i a l
Edit
d a ta
*
1
00
*
1
00
*
1
00
*
1
00
*
1
00
*
1
01
*
1
00
*
1
1.
*
1
1.
*
1
1.
*
1
1.
*
1
1.
*
1
1.
*
1
1.
*
1
0.
*
1
01
00
*
1
0
*
1
10.00
*
1
U n i ts
ms
%