Using Intelligent Output Terminals
Run Signal
When the [RUN] signal is selected as an
intelligent output terminal, the inverter outputs
a signal on that terminal when it is in Run
Mode. The output logic is active low, and is
the open collector type (switch to ground).
Option
Terminal
Code
Symbol
RUN
Valid for outputs:
Required settings
Notes:
The inverter outputs the [RUN] signal whenever
the inverter output exceeds the start frequency
specified by parameter . The start frequency
is the initial inverter output frequency when it turns
ON.
The example circuit for terminal [11] drives a relay
coil. Note the use of a diode to prevent the
negative going turn-off spike generated by the coil
from damaging the inverter's output transistor.
Function Name
Run Signal
11, 12, AL0 – AL2
(none)
[FW,RV]
Output
frequency
Run
signal
State
ON
when inverter is in Run Mode
OFF
when inverter is in Stop Mode
Example for terminal [11]
Inverter output
terminal circuit
Example for terminal [AL0], [AL1], [AL2]
Inverter logic
circuit board
36
1
0
start freq.
ON
Description
RUN
CM2
RY
RUN
AL0
AL1
AL2
Power
Load
supply
t
11