Standard Functions
NOTE: Marking [  ],[  ],[
 : Configuration changes are possible during operation.
: You cannot change the parameters during operation.
*
1: In case of (b031) soft lock selections"10", parameter changing during operation is
possible.
F u n c .
N a m e
C o d e
A001
Frequency source
A201
Frequency source,
nd
2
motor
A002
Run command source
Run command source,
A202
nd
2
motor
Base frequency
A003
Base frequency,
A203
nd
2
motor
A004
Maximum frequency
A204
Maximum frequency,
nd
2
motor
[AT] selection
A005
A011
[O] input active range start
frequency
*
1 ],in the table show following meaning.
" A" F u n c t i o n
D e s c r i p t i o n
Eight options; select codes:
00 POT on ext. operator
*Valid when connecting the
OPE-SR/SRmini
01 Control terminal
*Set to "01" when connecting the
WJ-VL or External volume via
control terminal
02 Function F001 setting
03 Modbus network input
04 Option
06 Pulse train input
07 via EzSQ
10 Calculate function output
Four options; select codes:
01 Control terminal
02 Run key on keypad, or
digital operator
03 Modbus network input
04 Option
Settable from 30 Hz to the
maximum frequency(A004)
Settable from 30 Hz to the 2
maximum frequency(A204)
Settable from the base
frequency to 400 Hz
Settable from the 2
frequency to 400 Hz
Three options; select codes:
00...Select between [O] and [OI]
at [AT] (ON=OI, OFF=O)
02...Select between [O] and
external POT at [AT]
(ON=POT, OFF=O)
03...Select between [OI] and
external POT at [AT]
(ON=POT, OFF=OI)
The output frequency
corresponding to the analog
input range starting point,
range is 0.00 to 400.0
nd
nd
base
51
D e f a u l ts
Run
Mode
I n i t i a l
U n i ts
Edit
d a ta
02
02
02
02
60.0
60.0
60.0
60.0
00
*
1
0.00
Hz
Hz
Hz
Hz
Hz

Advertisement