Example Wiring Diagram
The schematic diagram below provides a general example of logic connector wiring, in
addition to basic power and motor wiring converted in Chapter 2 of the Instruction Manual.
The goal of this chapter is to help you determine the proper connections for the various
terminals shown below for your application needs.
Breaker, MCCB
or GFI
Power source,
3-phase or
1-phase, per
inverter model
Jumper wire
(Sink logic)
Thermistor
Intelligent inputs,
7 terminals
NOTE: For the wiring
of intelligent I/O and
analog inputs, be sure
to use twisted pair /
shielded cable. Attach
the shielded wire for
each signal to its
respective common
terminal at the inverter
end only.
Input impedance of
each intelligent input is
4.7k
Meter
Meter
Analog reference
0~10VDC
4~20mA
Pulse train input
24Vdc 32kHz max.
GND for analog signals
R
(L1)
S
(L2)
T
N(L3)
24V
P24
+ -
PLC
L
Forward
1
2
Input
circuits
3/GS1
[5] configurable as
4/GS2
discrete input or
thermistor input
5/PTC
6
7/EB
EO
L
AM
L
H
O
Apprx.10k
OI
Apprx.100
EA
L
WJ200
L
GND for logic inputs
Output circuit
Termination resistor (200)
(Change by slide switch)
RS485
transceiver
L
10Vdc
+
-
RS485
transceiver
L
USB
transceiver
Option port
controller
L
20
U
(T1)
V
(T2)
W
(T3)
PD/+1
P/+
Brake
resistor
RB
(optional)
N/-
AL1
Relay contacts,
type 1 Form C
AL0
AL2
Open collector output
Freq. arrival signal
11/EDM
Load
Load
12
CM2
GND for logic outputs
SP
Serial communication port
(RS485/Modbus)
NOTE: Common for
SN
RJ45 port
(Optional operator port)
L
USB (mini-B) port
(PC communication port)
USB power: Self power
L
Option port connector
L
Motor
DC reactor
(optional)
Braking
unit (optional)
+
-
RS485 is "L".