No.
Component
13
AC Charger
14
AC Charger
Issue 02 (2023-01-13)
Alarm Name
Alarm
Severity
High
Minor
Temperature
Cable
Critical
Connection
Abnormal
Copyright © Huawei Technologies Co., Ltd.
Possible
Suggestion
Cause
The possible
Step 1 Check whether the
causes are as
charger is exposed to strong
follows:
sunlight.
1. The
If yes, shield the charger from
ambient
direct sunlight. If the alarm
temperature
persists, go to the next step.
of the
If no, go to the next step.
charger is
Step 2 Check whether there are
too high.
heat sources around.
2. The cable
If yes, keep the charger away
is short-
from heat sources. If the alarm
circuited.
persists, go to the next step.
If no, go to the next step.
Step 3 Check whether the
ambient temperature is lower
than 40°C.
If yes, replace the charger when
the alarm persists.
If no, restart the charger after
the ambient temperature drops.
Wait for 1 minute and check
whether the alarm is cleared. If
the alarm persists, replace the
charger.
The possible
Step 1 Check whether the
causes are as
charger is properly grounded.
follows:
If yes, go to the next step.
1. The
If no, contact your electrician to
charger is
ground the charger correctly.
not
Step 2 Contact the electrician to
grounded.
check whether the live wire and
2. The live
neutral wire are reversely
wire and
connected (by checking
neutral wire
whether the voltage between
are reversely
the PE wire and neutral wire is
connected.
greater than 60 V).
If yes, contact your electrician
to connect the wires correctly.
If no, replace the charger.