Huawei PV+ESS+Charger Solution User Manual page 70

Table of Contents

Advertisement

PV+ESS+Charger Solution
User Manual
No.
Component
3
Charging
Connector
4
Charging
Connector
Issue 02 (2023-01-13)
Alarm Name
Alarm
Severity
Control Pilot
Minor
Circuit Fault
Electric
Critical
Leakage
Copyright © Huawei Technologies Co., Ltd.
Possible
Suggestion
Cause
The possible
Step 1 Replace the charging
causes are as
connector and check whether
follows:
the alarm is cleared.
1. The
If yes, no further action is
charging
required.
cable
If no, go to the next step.
connection is
Step 2 Restart the charger and
poor.
check whether the alarm is
2. The
cleared 1 minute later.
control pilot
If yes, no further action is
circuit of the
required.
charging
If no, replace the charger.
connector is
faulty.
The possible
Step 1 Check whether the
causes are as
charging connector is inserted
follows:
into the charging port of the
vehicle.
1. The
charging
If yes, go to the next step.
cable is
If no, replace the charger.
damaged.
Step 2 Restart the charger, use
2. The PE
a simulator or another vehicle
cable inside
for charging, and check whether
the vehicle is
the alarm persists.
connected to
If yes, go to the next step.
the power
If no, the vehicle is faulty.
cable.
Step 3 Check whether the
insulation layer of the charging
cable is damaged.
If yes, replace the charging
cable. If the alarm persists,
replace the charger.
If no, replace the charger.