Canon DP-V2730 Operation Manual page 58

Video display
Table of Contents

Advertisement

OSD Menu
Sub Menu
1
Pixel Value Check
58
Enable
H Position
V Position
Reset Position
Chromaticity Diagram
Multi Information View
Test Pattern
Measures and displays the RGB value of the specified pixel (cursor) position. When [Gamma/EOTF]
is set to [SMPTE ST 2084 (PQ)] or [Hybrid Log-Gamma], the brightness value is also displayed.
• The non-constant value is displayed even if [2020 Constant Luminance] is set to [Constant].
On, Off
Switches the pixel value check On, Off.
1 to 4096 (960)
Sets the pixel position (horizontal).
1 to 2160 (540)
Sets the pixel position (vertical).
Normal
Sets operation when the RESET button is pressed.
Around Peak
Luminance
[Normal]: Resets the value to the default value.
[Around Peak Luminance]: Moves closer to the area of peak luminance
On, Off
Switches the chromaticity diagram On, Off.
[On]: Displays the chromaticity diagram. The chromaticity diagram is
ž [Color Gamut]: ITU-R BT.2020, ITU-R BT.709
ž [ Gamma/EOTF]: 1.0, 2.2, 2.35, 2.4, 2.6, SMPTE ST 2084 (PQ),
On, Off
Temporarily reduces the video display area so that the various video
information displays do not overlap. The displayed video information is as
follows.
ž T ime Code, Audio Level Meter, Wave Form Monitor, Vector Scope,
Histogram, Frame Luminance Monitor and Chromaticity Diagram
White (1023)
Sets the test pattern built into the main unit.
White (940)
• If the power is turned off once and then back on, the test pattern will not be
Gray
displayed.
Black (64)
• The test pattern will be erased in the following cases:
Black (0)
- When a channel is changed using the CH button, F button assigned for
Ramp
Color Bars
- When changing [Input Configuration] or [Select Input Signal] under [Channel
Color Bars (PQ Full)
Color Bars (PQ Limited)
- When [Reset All Settings] is executed
Color Bars (HLG)
PLUGE
PLUGE (PQ/HLG)
Off
Setting Options (Bold: factory default)
inside the display image.
displayed only when [Color Gamut] and [Gamma/EOTF] are set as
shown below.
Hybrid Log-Gamma
Channel UP/Channel DOWN, or [Select Channel] under [Channel Settings]
Settings]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp-v1830

Table of Contents