Lockout Threshold; Autocallback Timer; Break Length - Motorola V.3400 User Manual

Hide thumbs Also See for V.3400:
Table of Contents

Advertisement

Callback Retry Delay S76
The length of time that the modem waits, after an unsuccessful attempt
to connect to the remote unit at the programmed callback number,
before trying to place the call again. Default is 15 seconds.
Bit
Value
7-0
0-255
Lockout Threshold S77
The number of incorrect remote user password attempts that can be
made before the call is dropped.
Bit
Value
7-0
0-255
Autocallback Timer S78
The S78 register specifies the time in seconds that the modem waits
before initiating autocallback. The default is 30 seconds.
Bit
Value
7-0
0-255
Break Length S79
The S79 register sets the length of the break sent to the DTE when a
break signal is received. Range from 1-255 in 20 ms increments.
Default is 35 (700 ms).
Bit
Value
7-0
0-255
\B
\Bn
Command
Time in seconds (0 = disable)
Command
Number of incorrect password attempts (0 =
disable)
Command
Time in seconds before autocallback
Command
Send break
Set break length (n=1-255)
Description
Description
Description
Description
V.3400
Status Registers
10-25

Advertisement

Table of Contents
loading

Table of Contents