AIR-CONDITIONING & HEATING INSTALLATION - ASSEMBLY Continued
24. Pick up the wiring harness and connect the 2 pole plug with
green cable to the pressure plug.
25. Connect the 2 pole plugs (red/brown) (Q) to the fans on the
roof (when installed later). Refer to Fig 63 (Q).
26. Put canvas covering (R) onto tarred hoses to prevent them
from sticking to the roof. Refer to Fig 64 (R).
27. Run the rest of the wiring harness inside the left hand top
cab rail to the front of the roof space.
28. Connect the other end of the harness to the blower and
switches in accordance with the wiring diagram.
29. Fix the cables to hoses with cable ties.
30. Remove the blanking plate from the top of the roof. Refer
to Fig 65.
31. Screw the two axial fans to the underside of the roof. At the
same time attach the mesh screen to the top surface of the
roof. Refer to Fig 66.
32. Refit the roof ensuring that the electrical connections are
made between harness and axial fans.
33. Ensure that the air conditioning hoses and the water hoses
have their protective sleeve fitted. The sleeve should
continue 100mm inside cab posts. Refer to Fig 67.
34. Cable tie the hoses together to prevent scuffing.
Heater hose connection
Follow the instructions in the relevant section of this manual for
installing the Heater only. The connection details are the same
for all models of mower for which these parts are suitable.