Application Examples
Program the frequency converter as follows:
Parameter
H-08 Reverse Lock
E-01 Terminal 18 Digital Input
E-02 Terminal 19 Digital Input
E-24 Function Relay
O-03 Control Word Timeout Time
O-04 Control Word Timeout Function
O-10 Control Word Profile
O-50 Coasting Select
O-51 Quick Stop Select
O-52 DC Brake Select
O-53 Start Select
O-54 Reversing Select
O-55 Set-up Select
O-56 Preset Reference Select
PB-16 PCD Read Configuration
PROFINET Operating Instruction
Setting
Both directions [2]
No operation [0]
Reversing [10]
Control word bit 11/12 [36/37]
1 sec
Stop [2]
GE Drive Profile [0]
Network [1]
Network [1]
Network [1]
Network [1]
Logic AND [2]
Network [1]
Network [1]
Sub index [2] DR-16 Torque [Nm]
Sub indes [3] DR-60 Digital Input