How to Configure the System
5
5
The configuration tool automatically assigns addresses in the peripheral address area. In this example the input and output area
have the following configuration:
PPO type 6:
PCD word number
Input address
Set-up
Table 5.1 PCD Read (Drive to PLC)
PCD word number
Output address
Set-up
Table 5.2 PCD Write (PLC to Drive)
The PCDs have to be assigned via PB-16 PCD Read Configuration for inputs and PB-15 PCD Write Configuration for outputs.
Download the configuration file to the PLC. The PROFINET system should be able to go online and it will start to exchange data
when the PLC is set to Run mode.
18
PROFINET Operating Instruction
0
1
256-257
258-259
STW
MAV
0
1
256-257
258-259
CTW
MRV
2
260-261
PB-16 PCD Read Configuration.2
2
260-261
PB-15 PCD Write Configuration.2
3
262-263
PB-16 PCD Read Configuration.3
3
262-263
PB-15 PCD Write Configuration.3