Operation via the CB Gate user interface
8.2 Menu items
8.2.3

"Black list" menu item

The "Black list" menu item is divided into the following areas:
• Settings
• Black listed transponders in PLC
Figure 8-4
Settings
You can enable or disable the Black list filter algorithm in the "Settings" area. Note that the
algorithm can only be enabled/disabled when the CB Gate is disabled ("Home > Enable
Tiregate > Off").
Table 8- 6
Parameter
Disable Black list
Black listed transponders in PLC
The five transponders currently in the Black list are shown in the "Black listed transponders in
PLC" area. They are filtered out in the next read operations.
You can delete all entries from the list with the "Delete" button.
48
"Black list" menu item
Description of the "Settings" parameters
Description
If the function is enabled, transponders that have already been processed are
hidden in a targeted manner.
Note: The "Black List" is enabled in the delivery state. This ensures that
transponders are not read multiple times in succession. A transponder is only
detected again if at least five other transponders have been read between
the first and the following read operation.
The recommendation is to disable the Black list for test purposes only.
Operating Instructions, 08/2022, C79000-G8976-C671-01