Assignment Of Fch Related Data; Figure 5-27 Mbct Command Display - NEC NEAX 2400 IPX Manual

Fusion network
Hide thumbs Also See for NEAX 2400 IPX:
Table of Contents

Advertisement

DATA PROGRAMMING

Assignment of FCH Related Data

STEP 3: MBCT
Unbusy the connection trunk data assigned in the previous step using MBCT (Make Busy of
Connection Trunk) command. This step is required for both B-channel and D-channel trunk. The
MBCT command should look similar to
MBCT (Make Busy of Connection Trunk for Local)
WRT?
Y
7. Assignment of FCH Related Data
STEP 1: For Fusion with FCH only:
Assign FCH Number on an FCH (PA-FCHA) circuit card basis.
The FCH Number must conform to the following conditions:
FCH Number range must be between 1 and 255.
At the network level, the same FCH Numbers can be assigned. However, they must be unique at the
node level.
CHAPTER 5
Page 84
Revision 1.0
C_RT
C_TK
1
5
MB
0

Figure 5-27 MBCT Command Display

Figure
5-27.
C_RT: 1-1023
C_TK: 1- 4095
Make Busy Information
0: Make Idle
1: Make Busy (Outgoing)
NDA-24299

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents