Autolist; Record Set Up - JVC SW-D8000U Instruction Manual

Table of Contents

Advertisement

SW-D8000U, 16CH. COLOR VIDEO MULTIPLEXER
NOTE:
The camera sequence list for Monitor-A and Monitor-B is programmed using the
AutoList™ feature.
To start full screen sequencing on Monitor-A or B:
Select any full screen display by pressing the camera number, and then
press the SEQUENCE key.
To stop full screen sequencing on Monitor-A or B:
Press SEQUENCE again, or press any camera key, or press the
MULTISCREEN key.
4.7

AUTOLIST™

The operator can easily change the DEFAULT of all camera sequencing by using the AutoList™
function. AutoList™ sequence lists exist for Monitor-A, full-screen and Monitor-B. An AutoList™
also exists for the PLAY mode. DEFAULT settings for the lists are all cameras included, dwell time
taken from menu. The DEFAULT dwell time is 3 seconds.
An AutoList™ recording is started in full-screen mode (LIVE or PLAY) by
pressing ALARM and SEQUENCE keys simultaneously. Then select cameras
in order of the sequence desired and at time desired for individual dwell times.
Press the SEQUENCE key to stop recording of the AutoList™. Dwell times of up (time between key
presses) to 30 seconds are allowed. A maximum of 32 cameras may be put into an AutoList™.
Pressing any key other than a valid camera key or the SEQUENCE key during recording will void
the AutoList™. To return to the DEFAULT of all cameras included in the sequence list, with a fixed
menu programmed dwell time, go to the SEQUENCING menu and change the dwell time.
4.8

RECORD SET UP

This RECORD LIST option is used to specify the order in which images are to be recorded from the
different camera inputs. You can have up to 30 camera numbers in any order. This allows the
same camera number to be repeated in the list as required to increase the update rate or camera
priority on the VCR. In this menu, you can specify the normal record speed for the VCR (time lapse
speed) and the alarm record speed (typically 2 hour mode). The following pull down menu is
displayed.
You may wish to review the description of "How multiplexed recording works" in Section 2.0.
RECORD LIST
A programmer programmed RECORD LIST controls the sequence in which the single fields from
each camera are multiplexed to the VCR during record mode. The list can contain any camera
several times. For example, if the list is set to the equivalent of "1 2 3 3 3 4 5 6 7 8 5__", then
camera 3 will be recorded once in the record list cycle, but for three times the selected dwell time,
and camera 5 will be recorded twice in the cycle. For a multiplexer, the programming for camera 5
44
JVC PROFESSIONAL, IMAGING PRODUCTS
Record List
Normal Record Speed
Alarm Record Speed
Exit