Sharp AR-FX7 Service Manual page 67

Digital multifunctional system option
Hide thumbs Also See for AR-FX7:
Table of Contents

Advertisement

SW110 No.1–No.4 Print lead edge adjustment (Rear edge
adjustment)
Setup of print image area void
The quantity of void at the lead edge in sub scan direction can be
adjusted. When the set value is increased, the image void is increased.
Setup of SIM 50-9 is reflected.
0 to ±112 dots in the interval of 16 dots
Default: 48 dots
SW110 No.5–No.8 Print lead edge adjustment (left edge
position) rear
Setup of print image area void
The quantity of void at the left edge in main scan direction can be
adjusted. When the set value is increased, the image void is increased.
Setup of SIM 50-9 is reflected.
0 to ±112 dots in the interval of 16 dots
Default: 48 dots
SW111 No.1–No.4 Print lead edge adjustment (lead edge
position) rear
Setup of print image area void
The quantity of void at the lead edge in sub scan direction can be
adjusted. When the set value is increased, the image void is increased.
Setup of SIM 50-9 is reflected.
0 to ±112 lines in the interval of 16 lines
Default: 48 lines
SW111 No.5–No.8 Print lead edge adjustment (rear edge
position) rear
Setup of print image area void
The quantity of void at the lead edge in sub scan direction can be
adjusted. When the set value is increased, the image void is increased.
Setup of SIM 50-9 is reflected.
0 to ±112 lines in the interval of 16 lines
Default: 48 lines
SW112 No.1–No.8 Print magnification ratio adjustment
(horizontal)
Used to adjust the print magnification radio in main scan direction.
Setup of SIM 48-9 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW113 No.1–No.8 Print magnification radio adjustment
(vertical)
Used to adjust the print magnification radio in sub scan direction.
Setup of SIM 48-9 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW114 No.1–No.4 Scan effective image area (OC) vertical
lead edge image loss
Used to set the image loss in OC scan image area.
The quantity of image loss at the lead edge in sub scan direction can
be adjusted. When the set value is increased, the lead edge image
loss quantity is increased.
Setup of SIM 50-8 is reflected.
0 to ±56 lines in the interval of 8 lines
Default: 0 lines
SW114 No.5–No.8 Vertical rear edge image loss in scan
effective image area (OC)
Used to set the image loss in OC scan image area.
The quantity of image loss at the rear edge in sub scan direction can
be adjusted. When the set value is increased, the image loss quantity
at the rear edge is increased.
Setup of SIM 50-8 is reflected.
0 to ±56 lines in the interval of 8 lines
Default: 0 lines
SW115 No.1–No.4 Scan effective image area (OC)
horizontal left edge image loss
Used to set the left edge image loss of main scan in OC scan of FAX.
Setup of SIM 50-8 is reflected.
0 to ±56 lines in the interval of 8 lines
Default: 0 lines
SW115 No.5–No.8 Scan effective image area (OC)
horizontal right edge image loss
Used to set the right edge image loss of main scan in OC scan of FAX.
Setup of SIM 50-8 is reflected.
0 to ±56 lines in the interval of 8 lines
Default: 0 lines
SW116 No.1–No.8 Scan magnification adjustment OC
(horizontal)
Used to adjust the OC scan magnification ratio in main scan direction.
Setup of SIM 48-8 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW117 No.1–No.8 Scan magnification ratio adjustment
OC (vertical)
Used to adjust the OC scan magnification ratio in sub scan direction.
Setup of SIM 48-8 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW118 No.1–No.4 Scan effective image area (SPF) vertical
lead edge image loss
Used to set the image loss in SPF scan image area.
The quantity of image loss at the lead edge in sub scan direction can
be adjusted. When the set value is increased, the lead edge image
loss quantity is increased.
Setup of SIM 50-8 is reflected.
0 to ±56 lines in the interval of 81 lines
Default: 0 lines
SW118 No.5–No.8 Vertical rear edge image loss in scan
effective image area (SPF)
Used to set the image loss in SPF scan image area.
The quantity of image loss at the rear edge in sub scan direction can
be adjusted. When the set value is increased, the image loss quantity
at the rear edge is increased.
Setup of SIM 50-8 is reflected.
0 to ±14 lines in the interval of 21 lines
Default: +0 lines
SW119 No.1–No.4 Scan effective image area (SPF)
horizontal left edge image loss
Used to set the left edge image loss of main scan in SPF scan of FAX.
Setup of SIM 50-8 is reflected.
0 to ±56 dots in the interval of 8 dots
Default: +0 dots
AR-FX7 SOFT SWITCH 7 - 40

Advertisement

Table of Contents
loading

Table of Contents