Item
4
PROTOCOL
Protocol error list
Regardless of soft SW38-1 status, the
protocol monitor of the preceding
communication is printed. (Printing is
allowed at any time before starting the
next communication.) For this operation,
the protocol monitor of one
communication is always buffered.
Note: Executable only when the FAX is installed.
66-22
Purpose
Setting
Function
Handset sound volume adjustment (Japan only)
(Purpose)
Section
FAX
Item
Operation
Operation/procedure
1. Select the set volume. (Max., Middle, Min.)
2. Press the [START] key.
Switch of 1, 2, and 3 can be made during execution of the simulation.
During execution of the simulation, sounds are generated.
Note: Executable only when the FAX is installed.
66-24
Purpose
Data clear
Function
Used to clear the FAST storage data. (SEC only)
(Purpose)
Section
FAX
Item
Data
Operation/procedure
Select "1: YES" with the 10-key and press the [START] key. The FAST
storage data are cleared. (When "2: NO" is selected, the simulation is
canceled.)
Note: Executable only when the FAX is installed.
Content
Initializing
AR-FX7 SIMULATION 6 - 11
66-30
Purpose
Operation test/check
Function (Purpose)
Used to set the TEL/LIU.
Section
FAX
Item
Operation
Operation/procedure
When the relay state of the polarity reverse relay, the handset hook
switch, or the external telephone hook switch is changed, the content
of change is displayed regardless of the soft SW setup (real time). The
display of change is kept until an interruption command is supplied by
pressing the [CUSTOM SETTINGS] key.
Item
Signal low
HS2
HS1
RHS
EXHS
Note: Executable only when the FAX is installed.
66-31
Purpose
Setting
Function (Purpose)
Used to set the TEL/LIU.
Section
FAX
Item
Operation
Operation/Procedure
1. Enter the set value. (Valid only 0 to 8)
2. The entered bit is alternatively switched between "0" and 1" and
the target signal name is highlighted.
3. Press the [START] key to send the signal.
When the [CUSTUM SETTINGS] key is pressed, the output is termi-
nated.
Note: Executable only when the FAX is installed.
66-32
Purpose
Operation test/check
Function (Purpose)
Receive data check
Section
FAX
Item
Operation
Operation/procedure
The fixed data received from the line are checked and the result is dis-
played.
When data are coincident, "OK" is displayed. When not, "NG" is dis-
played.
Note: Executable only when the FAX is installed.
Notification contents
Signal high
ON
OFF
ON
OFF
ON
OFF
ON
OFF
1 2 3 4 5
00001