SW
Data
Items
No.
No.
1
Inhibited to use
2
3
S
4
W
5
133
6
7
8
3. Soft switch descriptions
SW1 No.1–No.8 Country information
Destination setup
SW2 No.1, No.2 SIM language information
SIM language selection
SW2 No.3–No.8 Language information
Language selection
SW3 No. 1 Sharp machine mode
Sharp machine mode setup
Default: 1 (ON)
SW3 No. 2 Sharp machine mode (F code)
Sharp machine mode (F code) setup
Default: 0 (OFF)
SW3 No. 3 FAST mode
Used to set Enable/Disable of FAST operation. (SEC only)
This SW must be set to enable FAST operation by the serviceman.
Default: 0 (NO)
SW3 No. 4 Center number in FAST
Center number setup in FAST
Default: 0 (Service-No.)
SW3 No.5–No.7 Maintenance cycle
Setup for judgment of consumable parts notification when using the
F.A.S.T. function.
This setup should be the same as SIM21-1 setup.
Default: 0 0 1 (75K)
SW3 No. 8 Maintenance system
Setting of the machine model for judgment of consumable parts sys-
tem in the FAST function
Default: 0 (AR)
SW4 No.1–No.8 Inhibited to use.
SW5 No. 1 Initialization control inside program
Used to set whether the all soft switches are initialized or not.
When set to 1, the initialization is made.
When set to 0, No initialization is made.
Default: 0 (nothing is made)
SW5 No. 2 For FAX debug
Used to set ON/OFF of FAX debug mode.
When set to 1, debug mode is ON.
When set to 0, debug mode is OFF.
Default: 0 (Debug mode OFF)
SW selection and functions
SW5 No. 3 Flash memory check measuring range
Operation check usually can be done by 256-byte check. Setting to 1
will check all areas of the flash memory. Note that it takes about 20
min.
Default: 0 (256 bytes)
SW5 No. 4 ICU UART1 output
Used to set whether ICU UART 1 output is made or not.
Default: 1 (Output is not made)
SW5 No.5–No.8 24V reset wait time
Used to set the 24V reset wait time.
The set range is 0 to 750 by binary input.
Default: 500ms
SW6 No. 1 Auto/Manual default setup
Used to select Auto/Manual reception mode when turning on the
power. (When no external telephone is connected, do not select Man-
ual. However, setup is possible and reception can be made by on-
hook.)
When set to 1, manual reception.
When set to 0, auto reception.
Default: 0 (Auto reception)
SW6 No. 2 Inhibited to use.
SW6 No.3, No.4 Size specification
Used to set inch series or AB series for recording paper when printing
received documents.
Normally there is no need to change from "Follow the machine infor-
mation."
Default: 0 1 (follows the machine information)
SW6 No. 5 Inhibited to use.
SW6 No. 6 Memory transmission/direction transmission
default setup
Used to select Memory/Direction transmission when the power is
turned on and the time out is cleared.
When set to 1, direct transmission is selected when the power is turned
on and the time out is cleared.
When set to 0, memory transmission is selected when the power is
turned on and the time out is cleared.
Default: 0 (Memory transmission)
SW6 No. 7 Quick memory transmission
Used to set whether quick memory transmission (transmission of ring-
ing before completion of scanning) is performed or not. Linked with the
key operator program menu.
Default: 1 (Allowed)
AR-FX7 SOFT SWITCH 7 - 27
Default value
Remarks
0
0
1
1
0
0
0
0

Advertisement