SW22 No. 8 DP dial pulse number process
Used to set the process of the number of DP dialing pulse.
1: 10-N
0: Normal (N)
Default: 0 (Normal N)
SW23 No.1 Inhibited to use.
SW23 No. 2 Monitoring polarity reversion during send
image
Used to set YES/NO of monitoring polarity reversion during communi-
cation on the dialing side.
When set to 1, polarity reversion is monitored.
When set to 0, polarity reversion is not monitored.
Default: 0 (NO) (fixed)
SW23 No. 3 Monitoring polarity reversion during
communication
Used to set whether the poolarity reversion is monitored or not during
dialing.
When set to 1, polarity reversion is monitored.
When set to 0, polarity reversion is not monitored.
Default: 0 (NO) (fixed)
SW23 No.4–No.8 Setting of time before dial (10PPS)
Used to set the time before dial (10PPS)
Setup is made in the range of 0 (50ms) – 31 (360ms) by binary input of
N in "X (ms) = (N × 10) + 50".
Default: 300ms
SW24 No.1–No.4 Inhibited to use.
SW24 No.5–No.8 Waiting time for OFF HOOK
Used to set the wait time of OFF HOOK.
The set range is 0 (50ms) – 15 (200ms) in the increment of 10ms by
binary input of N in "X (ms) = (N x 10) + 50".
Default: 100ms
SW25 No.1–No.4 Make time (10PPS) setup
Used to set the make rate when dialing at 10PPS.
The set range of N is 0 to 15 in binary input for the make rate of (N +26
ms), which ranges from 26 to 41 ms.
Default: 34ms (U.K., France) 41ms (Germany)
SW25 No.5–No.8 Inhibited to use.
SW26 No.1–No.5 DTMF signal send time
Used to set the send time when sending DTMF signal.
Setup is made in the range of 60 – 310ms by binary input of N in
"10(ms) × N" in the increment of 10ms.
N can be set in the range of 6 – 31.
When N is set to 0, it is the same as 110ms (N=11).
Default: 110ms
SW26 No.6–No.8 Minimum pause time (DTMF) setup
Used to set the minimum pause time (DTMF).
Setup is made in the range of 90 – 160ms by binary input of N in "X
(ms) = (N × 10) + 90" in the increment of 10ms.
N can be set in the range of 0 – 7.
Default: 120ms
SW27 No. 1 Inhibited to use.
SW27 No.2–No.4 Setting of time before dial (DTMF)
Used to set the time before dial (DTMF)
Setup is made in the range of 30 – 100ms by binary input of N in "X
(ms) = (N × 10) + 30" in the increment of 10ms.
N can be set in the range of 0 – 7.
Default: 50ms
SW27 No.5–No.8 Setting of DPMUTE OFF time after dial
Used to set DPMUTE OFF time after dial.
Setup is made in the range of 5 – 80ms by binary input of N in "X (ms)
= (N × 5) + 5" in the increment of 5ms.
N can be set in the range of 0 – 15.
Default: 50ms
SW28 No.1–No.4 Pause time setup
Used to set the pause time.
The set range is 1 sec to 15 sec by binary input.
When set to 0 sec, the same as the setup of 2 sec.
Default: 2sec
SW28 No.5, No.6 Flash send time
Used to set ON time of Flash pulse width to be sent in sending Flash
signal to the line.
Default: 0 0 (90ms) (Fixed to 0 except for Germany and France.)
SW28 No.7, No.8 Line open delay time in dial test
Used to set the line open delay time in dial test.
Default: 0 0 (2 sec)
SW29 No. 1 Communication record table automatic print
Used to set whether the communication record table is printed auto-
matically when each of transmission/reception data of communication
record table reaches 50 items.
When set to 1, the table is automatically printed.
When set to 0, the table is not printed though the data reaches 50
items.
Default: 0 (No print)
SW29 No. 2 Time specification of communication record
table
Used to set whether time is enabled or not in the output function of
communication record table at the specified time.
Linked with the key operator program.
Default: 0 (Inhibited)
SW29 No.3, No.4 Sequence of year, month, and day on the
LCD, the report, and the sender's record
Used to set the recording sequence of year, month, and day on the
LCD, reports, and the sender's record.
Default: Day, month, year
SW29 No.5–No.8 Call time setup in automatic
transmission (T0 timer setup)
Used to set the call time when call does not reach the other party in
auto send mode.
The set range is 30 to 75 sec in the increment of 5 sec by binary input
of "(5 sec × N) + 30 sec)".
N can be set in the range of 0 – 15. Setting to 10 – 15 (setup of 80 –
105 sec) comes the same as the setup of 45 sec.
Default: 45sec (N=3)
SW30 No.1–No.3 Inhibited to use.
SW30 No.4–No.8 Time specification print (o'clock) on the
communication report table
Used to set "o'clock" of the time (o'clock, min) when specifying the time
on the communication report table.
Setup is in the range of 0 – 23 (o'clock) by binary input.
When set to 24 – 31, the time is set to 0 o'clock.
Default: 0 o'clock
SW31 No.1, No.2 Inhibited to use.