Mitsubishi Electric KD Series User Manual page 85

Contact image sensor
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

Address
Register name
7000 LinePeriodCounter
7010 LedSelector
7014 LedPulseDivision
7018 LedPulseWidthA
701C LedPulseWidthB
7020 LedEffectivePeriod
7030 ShutterEnable
7034 ShutterEnd
7038 ShutterWidth_R
703C ShutterWidth_G
7040 ShutterWidth_B
7050 DarkCorrectionEnable R/W
DarkCorrectionExecut
7054
e
WhiteCorrectionEnabl
7070
e
7074 WhiteTarget_R
7078 WhiteTarget_G
707C WhiteTarget_B
TM-XJ101C
Appendix A: Control register list ②
R/W
Val
0
Set Line cycle (Internal sync mode)
R/W
To
65535
LED control
0:OFF
R/W
0 to 3
1: Upper-stream LED-A ON
2: Down-stream LED-B ON
3: Both Upper-stream (A) and Down-stream (B) ON
Set LED Pulse division
R/W
0 to 3
0:OFF, 1: 2 pulses, 2: 4 pulses, 3: 8 pulses
R/W 0 to 65535 Upper-stream LED-A lighting period or pulse width
R/W 0 to 65535 Down-stream LED-B lighting period or pulse width
R/W 0 to 65535 Set LED Effective Period
R/W
0 or 1
Set Electric shutter On/Off
R/W 0 to 32765 Set exposure end timing
R/W 1 to 32764 Set Red exposure period
R/W 1 to 32764 Set Green exposure period
R/W 1 to 32764 Set Blue exposure period
Set Dark correction On/Off
0 or 1
0:OFF /1:ON
R/W
1
Generate Dark correction data
Set White correction On/Off
R/W
0 or 1
0:OFF /1:ON
R/W 0 to 4095 Set Red White Correction Target value
R/W 0 to 4095 Set Green White Correction Target value
R/W 0 to 4095 Set Blue White Correction Target value
Result
0:OFF /1:ON
© Mitsubishi Electric Corporation
Initial
1749
0
0
450
450
692
0
130
1
1
1
0
-
0
4000
4000
4000
85