Mitsubishi Electric KD Series User Manual page 54

Contact image sensor
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

3-3-2 DC5V cable connection
(This cable is not included in the CIS product)
1)Connect ① DC5V power cable to CIS connectors V1/V3(for
L4) or V1/V2/V3(for L5/L6).
Type
Power for
CIS(+5V)
2) Fix CIS connectors and the cable by screws
CIS has locknut D20418-J3R (JAE) (M2.6, female).
Use M2.6 screw, M2.5 screw, M2.6 type JAE Lock
screw, etc., which are applicable to fix cable connectors.
Recommended screwing torque is 16 - 20 N*cm.
TM-XJ101C
3-3 Connections
V2
V3
Model
No.
L4
L5
L6
V1
V2
×
V3
【Remarks】
1) Do not screw with higher torque than recommended.
Otherwise, locknut on CIS may be loosened or removed
when you remove screws.
2) CIS does not support hot-swap.
Make sure to power off CIS before connecting / removing
cables. If the cables are connected / removed while
powered on, it may cause failure on CIS.
54
© Mitsubishi Electric Corporation

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kd6r1064cxl-nlKd6r1247cxl-nlKd6r1688cxl-nl

Table of Contents