Address
Register name
4014 LinkConfig
6004 Height
6008 Width
600C OffsetX
6010 PixelFormat
6014 AcquisitionStart
6018 AcquisitionStop
601C AcquisitionMode
6020 TestImageSelector
6024 TestLineRate
6028 TriggerMode
(*)The register values of less than 7000 of Address values need to be set on master and slave channels respectively.
TM-XJ101C
(*1)The setting values of Width of Master and Slave channels are respectively different.
Appendix A: Control register list ①
R/W
Val
0x40048,
0x40040,
Set Output data bitrate and number of output
0x40038,
channel0x40048:CXP6_X4,0x40040:CXP5_X4,0x40038:CXP3_X4
0x20048,
0x20048:CXP6_X2,0x20040:CXP5_X2,0x20038:CXP3_X2
R/W
0x20040,
0x10048:CXP6_X1,0x10040:CXP5_X1,0x10038:CXP3_X1
0x20038,
0x10048,
※CXP6=6.25 ,CXP5=5 ,CXP3=3.125 [Gbps/ch]
0x10040,
X1=Single(1ch) ,X2=Dual (2ch) ,X4=Quad(4ch)
0x10038
R
1
1Line fixed
Set number of output pixels in scan direction
R/W 0 to 16380
(output width)
R/W
0
Line pixel position offset 0 fixed
0x0401,
Switch image output format
0x0402,
R/W
0x0401:24bit RGB color, 0x0402:30bit RGB color
0x0101,
0x0101:8bit mono, 0x0102:10bit mono
0x0102
R/W
1
AcquisitionStart
R/W
1
AcquisitionStop
R
0
0x00000000(Continuous) fixed
Set test pattern
R/W
0 to 3
0:OFF /1:Grey ramp horizontal
Set line rate for test pattern
R/W 0 to 55000
Set a source of sync signal
R/W
0 or 1
0: Internal sync mode 1: External sync mode
(*1)
1:Start
1:Stop
2:Grey ramp vertical
/3:RGBW
�������� ��������[����] = (register value)
Result
© Mitsubishi Electric Corporation
Initial
0x40048
1
L4:12292/13000
L5:14016/15608
L6:14016/13156
/13000
0
0x0401
-
-
0
0
55000