Technical data
5.3 System data, connection values, dimensions and weight
5.3
System data, connection values, dimensions and weight
General technical data
The SIMOTION D410‑2 has an integrated fan.
Table 5-3
Dimensions and weight
Dimensions W x H x D
D410-2 DP
D410-2 DP/PN
Weight
•
•
Electrical connection values
Power supply
Ripple
Non-periodic overvoltage
Current consumption, typically
Starting current, typically
Power loss, typically
With no load on I/Os and no 24 V supply via DRIVE‑CLiQ or PROFIBUS interface
1)
Memory
Table 5-4
RAM (work memory)
RAM disk (load memory)
Retentive memory
(retain variables)
Persistent memory
(user data on CF card)
Work memory for Java applications
Non-volatile data buffering
buffer time, min.
Memory for system data
Diagnostic buffer (non-volatile)
84
General technical data
Without packaging
With packaging
1)
1)
Technical data for memory
73 x 186.8 x 74.4 mm
73 x 190.7 x 74.4 mm
•
830 g
•
1,000 g
24 VDC (permissible range: 20.4 ... 28.8 V)
Max. 5% at 24 VDC
Max. 35 VDC
(Condition: Max. 500 ms, 50 s recovery time, max.
10 results/h)
1)
< 0.8 A
3.0 A
< 20 W
120 MB (as of V5.3 SP1)
96 MB (V4.4 - V5.2 SP1)
48 MB (V4.3 SP1)
60 MB (as of V5.3 SP1)
47 MB (V4.4 - V5.2 SP1)
31 MB (V4.3 SP1)
At least 108 KB
2 GB CF card: At least 1.5 GB
1 GB CF card: At least 300 MB
20 MB
Unlimited (maintenance-free backup)
100 messages (SIMOTION)
100 messages (SINAMICS Integrated)
SIMOTION D410-2