Use Program 32-01 : Door Box Timers Setup to assign the timers used for the Door Box.
Program
The Door Box feature is called Door Phone when programming via WebPro and using a multiline terminal.
32
Input Data
Item
No.
01
Door Box Answer
Time
02
Door Lock Cancel
Time
03
Off-Premise Call For-
ward by Door Box
Disconnect Timer
Conditions
None
Feature Cross Reference
• Door Box
2-364

Program 32 : Door Box and Sensor Setup

Item
Input Data
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds

32-01 : Door Box Timers Setup

Description
A user can answer the door box during the
time specified in this program.
When a user activates the door lock re-
lease relay, this program specifies the
amount of time the door strike remains
open.
Define the conversation period for an Off-
Premise Call Forward by Door Box call.
When this timer expires, the caller hears
busy tone for three seconds (fixed time),
and the call is then disconnected.
Program 32 : Door Box and Sensor Setup
ISSUE 2.0
Default
30 seconds
10 seconds
60 seconds