Download Print this page

Mitsubishi Electric 800 Series Instruction Manual page 45

Hide thumbs Also See for 800 Series:

Advertisement

 Accessory
• Fan cover fixing screws: These screws are necessary for compliance with the EU Directives. (Refer to
Capacity
FR-F820-00105(2.2K) to FR-F820-00250(5.5K)
FR-F840-00083(3.7K), FR-F840-00126(5.5K)
FR-F820-00340(7.5K), FR-F820-00490(11K)
FR-F840-00170(7.5K), FR-F840-00250(11K)
FR-F820-00630(15K) to FR-F820-01250(30K)
FR-F840-00310(15K) to FR-F840-00620(30K)
• Eyebolt for hanging the inverter
Capacity
FR-F840-04320(185K) to FR-F840-06830(315K)
• Earthing (grounding) cable (1): For connection with a communication option
• CD-ROM (1): Including the Instruction Manual (Detailed) and other documents
 Installing a communication option
• To use a communication option, the enclosed earthing (grounding) cable needs to be installed. Install the cable according to the following procedure.
No.
1
Insert spacers into the mounting holes that will not be tightened with the option mounting screws.
2
Fit the connector of the communication option to the guide of the connector of the inverter, and insert the option as far as it goes. (Insert it to the inverter option connector 1.)
Remove the mounting screw (lower) of the Ethernet board earth plate. Fit the one terminal of the earthing (grounding) cable on the Ethernet board earth plate and fix it securely
3
to the inverter with the mounting screw (tightening torque 0.33 N•m to 0.40 N•m).
Fix the left part of the communication option securely with the option mounting screw, and place another terminal of the earthing (grounding) cable on the right part of the option
4
and fix the cable terminal and the option with the option mounting screw (tightening torque 0.33 N•m to 0.40 N•m).
If the screws are not tightened properly, the connector may not be inserted deep enough. Check the connector.
Spacer
Ethernet board
earth plate
Example of FR-A8NC
NOTE
• The number and shape of the spacers used differ depending on the communication option type. Refer to the Instruction Manual of each communication option for
details.
• The earth plate enclosed with a communication option is not used.
4
INVERTER INSTALLATION AND PRECAUTIONS
Screw size (mm)
Quantity
M3 × 35
1
M3 × 35
2
M4 × 40
2
Eyebolt size
Quantity
M12
2
Installation procedure
Option connector 1
Spacer
Earth cable
page
18.)
Mounting screw
Ethernet board
earth plate
Mounting screw
Spacer
Spacer
Mounting screw
Earth cable

Hide quick links:

Advertisement

loading