Cable Hole - Huawei SmartAX MA5600T Hardware Description

Multiservice access module
Hide thumbs Also See for SmartAX MA5600T:
Table of Contents

Advertisement

SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Hardware Description
NOTE

1.1.5 Cable Hole

The power cables and subscriber cables are led into the N63E-22 cabinet from the top and the
bottom of the cabinet. This topic describes the positions of cable holes at the top and the bottom
of the N63E-22 cabinet.
The cables of the N63E-22 cabinet can be routed in the overhead cabling mode or the underfloor
cabling mode.
l
l
Figure 1-9 Cable holes at the top of the cabinet (top view)
61.8
182.8
64.2
32.5
Issue 08 (2013-12-18)
l In
Figure 1-8
and
Figure
l For the I-type or C3-type PDU, use installation holes 79 and 82; for the B-type PDU, use installation
holes 79 and 81.
l The cabinet can also support an additional service subrack. In this case, it is recommended that the air
deflector (if not configured) be configured.
In the overhead cabling mode, external cables are led into the cabinet through the top of
the cabinet.
Figure 1-9
In the underfloor cabling mode, external cables are led into the cabinet through the bottom
of the cabinet.
Figure 1-10
31.5
Hole for clock
62
cables
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1-8, the filled holes are for floating nuts to fasten subracks.
shows the positions of cable holes at the top of the cabinet.
shows the positions of cable holes at the bottom of the cabinet.
Hole for signal
cables
Hole for power cables
and ground cables
Æ
15x224
Front door
Æ
15x130
Hole for uplink
optical fibers
1 Cabinet