1-36
Table 1-14: Default Values and Limits for SETUP Parameters
Default
Parameter
Transit-Time Parameters
Signal Low Limit
Cor. Peak Limit
Soundspeed ±
Limit
Velocity Low Limit
-40.0 ft/sec
(-12.142 m/
Velocity High Limit -40.0 ft/sec
(-12.142 m/
Acceleration Limit
15.0 ft/sec
(4.6 m/sec
Amp. Discrim Low
Amp. Discrim High
Delta T Offset
% of Peak
XMIT Sample Size
# Errors Allowed
Minimum Peak %
Limit
Maximum Peak %
Limit
T Window
R Window
TransFlection
Signal Low Limit
Velocity Low Limit
-40.0 ft/sec
(-12.142 m/
Velocity High Limit -40.0 ft/sec
(-12.142 m/
Rep Period 1
200 µsec
Rep Period 2
800 µsec
XMITS per
Reading
Value
Low Limit
40
-20
100
0
20%
1%
-100 ft/sec
(-30.48 m/sec)
sec)
-100 ft/sec
(-30.48 m/sec)
sec)
0
2
2
)
14
0
34
0
0
-1,000 µsec
50%
-100%
8
2
6
0
-100
-100
0
0
10
10
40
-20
-100 ft/sec
(-30.48 m/sec)
sec)
-100 ft/sec
(-30.48 m/sec)
sec)
100 µsec
100 µsec
5,000
1,024
Programming Site Data
High Limit
100
500
50%
+100 ft/sec
(+30.48
m/sec)
+100 ft/sec
(+30.48
m/sec)
2
100 ft/sec
2
(30 m/sec
)
100
100
1,000 µsec
100%
32
16
+100
+100
1,000
128
100
+100 ft/sec
(+30.48
m/sec)
+100 ft/sec
(+30.48
m/sec)
3,200 µsec
3,200 µsec
30,000

Advertisement