GE DigitalFlow DF868 Programming Manual page 134

Panametrics multipurpose ultrasonic liquid flowmeter
Hide thumbs Also See for DigitalFlow DF868:
Table of Contents

Advertisement

F1
ACTIV
Channel/Site status
ENERGY OPTION
F1**
F2*
F3*
OFF
TRANS
TRNFL
*Selections are
different depending
on installed options.
**Appears only on
2-channel DF868.
TOTALIZER OPTION
VOLUMETRIC UNITS
F1
F2
F3
F4
GAL/S
GAL/M
GAL/H
MGD
F4
F1
F2
F3
Mft3/d
BBL/S
BBL/M
BBL/H
F3
F4
F1
F2
A-I/M
A-I/H
A-I/D
A-F/S
VOL DECIMAL DIGITS
F1
F2
F3
F4
0
1
2
3
TOTALIZER UNITS
F1
F2
F3
F4
GAL
MGAL
ft^3
Mft^3
F1
F2
F3
F4
BBL
MBBL
AC-IN
AC-FT
TOT DECIMAL DIGITS
F1
F2
F3
F4
0
1
2
3
MASS FLOW OFF
MASS FLOW ON
Initial Setup
PROG
F1
F2
F3
F4
CH1
CH2
GLOBL
SAVE
Channel PROGRAM status
Channel PROGRAM
F2
SYSTM
CHANNEL LABEL
SITE/CHANNEL MESSAGE
F1
F2
OFF
ON
SYSTEM UNITS
F1
F2
ENG
METRC
F1
F2
AUTO
MNUAL
F1
F2
F3
ft3/s
ft3/m
ft3/h
(Wetted Type) (Clamp-On Type)
F4
F1
F2
BBL/D
MBL/D
A-I/S
F1
F3
F4
F1
STEEL
A-F/M
A-F/H
A-F/D
MASS FLOW
F1
F1
F2
F3
F4
CARBN
LB
KLB
MMLB
TONS
MASS FLOW TIME
F1
F2
F3
F4
/SEC
/MIN
/HR
/DAY
F1
F2
F3
F4
PIPE OD
0
1
2
3
F1
F2
inch
feet
MASS TOTALS
F1
F2
F3
F4
PIPE WALL
PATH LENGTH P
LB
KLB
MMLB
TONS
F1
inch
F1
F2
F3
F4
(TRNFL) (TRANS)
0
1
2
3
TRANSDUCER ANGLE
F3
F4
PIPE
I/O
See Figure A-3
TRANSDUCER NUMBER
F1
SPEC
SPECIAL TRANSDUCER
WEDGE TYPE
F1
F2
F3
RAYL
SHEAR
WETTD
FREQUENCY
F1
F2
F3
F4
500k
1MHz
2MHz
4MHz
Tw
(WETTD)
(RAYL/SHEAR)
WEDGE ANGLE
WEDGE SOUNDSPEED
PIPE MATERIAL
F2
F3
F4
F1
F2
F3
F4
IRON
Cu
Al
BRASS
CuNi
GLASS
PLSTC
F1
F2
F3
PYREX
FLINT
F2
F1
F2
SS
DUCT
CAST
F1
F2
F1
30%Ni
10%Ni
NYLON
POLYE
F4
PVC
ACRYL
PIPE OD
F1
F2
F3
F4
F3
F4
inch
feet
in/PI
ft/PI
in/PI
ft/PI
PIPE WALL
LINING
F1
F2
F2
NO
YES
feet
LINING MATERIAL
AXIAL LENGTH L
F1
F2
F3
F4
F1
F2
TAR
PYREX
ASBES
MORTR
RUBBR
inch
feet
LINING SOUNDSPEED
LINING THICKNESS
NOTE: Plain text represents prompt area messages and
boxed text represents option bar choices.
F1
Fx represent function keys to select option bar choices.
SETUP
See Figure A-3
(TRNFL) (TRANS)
TRACKING WINDOWS?
F1
F2
NO
YES
FLUID TYPE
F1
F2
F3
F4
F1
WATER
OIL
METH
ETH
LN2
FREON
F1
F2
F3
F4
NORML
SEA
LUBE
CRUDE
WATER
TEMPERATURE
FLUID SOUNDSPEED
F1
FLUID TYPE
OTHER
F1
F2
F3
F4
W100
W260
OIL
OTHER
PIPE SOUNDSPEED
MINIMUM SOUNDSPEED
MAXIMUM SOUNDSPEED
REYNOLDS CORRECTION
F1
F2
F2
F3
OFF
ON
POLYP
KINEMATIC VISCOSITY or
F1
TEMP/KV table active
CALIBRATION FACTOR
(Clamp-on Transducers)
(Wetted Transducers)
(TRANS) (TRNFL)
DEPTH OF REFLECTOR
NUMBER OF TRAVERSES
F1
F2
F3
F4
1(Z)
2(V)
3
4
TRANSDUCER SPACING
F1
F2
F3
TEFLN
OTHER
March 2008
F2
F3
OTHER
F1
5
A-1

Advertisement

Table of Contents
loading

Table of Contents