TX line
Figure 20.
Cabling an FC E1/T1 75 Ω transmission unit
1.
2.
3.
Cabling an FC E1/T1 120/100 Ω transmission unit
DN991456
© Nokia Corporation
Issue 3 en
Nokia Proprietary and Confidential
All manuals and user guides at all-guides.com
FC E1/T1
75
Grounding
bridge
RX line
Cabling alternatives for the FC E1/T1 transmission unit
If you want to remove the grounding bridge (see Figure 20), use a 10 mm
hexagon socket to loosen both connectors and pull out the bridge. Re-
tighten the connectors.
Connect the connector of the received (RX) signal line to the 75 Ω RX
connector on the FC E1/T1 front panel.
Connect the connector of the transmitted (TX) signal line to the 75 Ω TX
connector on the FC E1/T1 front panel.
Connect the connector of TX/RX signal line to the 100/120 Ω TX/RX
connector on the FC E1/T1 front panel (see Figure 20). Tighten the
connector nut properly.
120/100
RX/TX line
Cabinet cabling