9.2 Changing the Speed During JOG Operation

The target speed can be changed during the JOG operation.
Setting
The parameters necessary for the setting of the JOG operation are specified by the Configurator PM.
The unit is set to pulse.
Item
Acceleration/deceleration pattern
Acceleration time 1 (ms)
Deceleration time 1 (ms)
Target speed 1
Acceleration time 2 (ms)
Deceleration time 2 (ms)
Target speed 2
Operation diagram
Operations of each contact
The BUSY flag (X18) indicating the state that a motor is running turns on when the JOG operation
-
started, and it turns off when the operation completed.
The target speed can be changed freely in the JOG operation. Use a program to change the target
-
speed.
The operation done flag (X20) indicating the state that an operation completed turns on when the JOG
-
operation completed, and it will be held until any operation among the position control, JOG operation,
home return and pulser operation starts.
9-4
Setting example
0: Linear acceleration/deceleration
100 ms
50 ms
10000 pps
200 ms
150 ms
20000 pps
Allowable range
0: Linear acceleration/deceleration
1: S-shaped acceleration/deceleration
0 to 10000 ms
0 to 10000 ms
Pulse: 1 to 32,767,000 pps
m: 1 to 32,767, 000 m/s
Inch: 0.001 to 32,767.000 inch/s
degree:0.001 to 32,767.000 rev/s
0 to 10000 ms
0 to 10000 ms
Pulse: 1 to 32,767,000 pps
m: 1 to 32,767, 000 m/s
Inch: 0.001 to 32,767.000 inch/s
degree:0.001 to 32,767.000 rev/s