Mitsubishi Electric LOSSNAY LGH-F300RX5-E Handbook page 15

Hide thumbs Also See for LOSSNAY LGH-F300RX5-E:
Table of Contents

Advertisement

System
Classification
Details
Systems
Mitsubishi
inter-
City Multi
locked
air condi-
with
tioner
( MA remote
external
devices
controller
( air
or ME
condi-
remote
controller )
tioning
units )
Central
Central/
control
independ-
system
ent control
for
of multiple
Lossnay
Lossnay
only
units
* Refer to the technical documentation for details about M-NET system design.
System Diagram
When using PZ-60DR-E
Lossnay
City Multi
Indoor unit
M-NET Remote
MA
Lossnay remote controller
M-NET
(PZ-60DR-E)
transmission
(Operation without a remote
cable
controller is also possible.)
When using PZ-52SF-E
Lossnay
City Multi
indoor unit
Indoor unit
M-NET Remote
MA
R2
M-NET
Remote controller for M-NET
transmission
(PZ-52SF-E)
cable
(Operation without a remote
controller is also possible.)
Remote controller : Terminal block for trans-
mission cable between
PZ-60DR-E and Lossnay unit
M-NET
: M-NET transmission cable
terminal block
R1
: PZ-60DR-E
R2
: PZ-52SF-E
When using PZ-60DR-E
System controller
Power supply unit
SC
Power supply
Group 1
Lossnay
Lossnay
Lossnay
R1
Remote controller (PZ-60DR-E)
Group 3
Lossnay Lossnay
R1
When using PZ-52SF-E
Power supply unit
M-NET controller
SC
Power supply
Group 1
Lossnay
Lossnay
Lossnay
R2
Remote controller for M-NET
(PZ-52SF-E)
Group 3
Lossnay
Lossnay
R2
• Lossnay can be interlocked
with a maximum of 16 air
conditioning units.
Transmission
• Lossnay can be started/
controller
cable between
stopped, and switched
the remote
between High and Low fan
controller and
R1
Lossnay
speed by an air conditioner
remote controller.
• Lossnay stand-alone opera-
tion is permitted from an air
conditioner remote control-
ler.
• Having PZ-60DR-E or
PZ-52SF-E permits last
controller
touch priority operation with
the air conditioner remote
controller and the Lossnay
remote controller.
*1: PZ-41SLB-E cannot be
*2: PZ-60DR-E and PZ-52SF-E
• Lossnay batch/independent
( group ) control is permitted
by system controller.
• Operation of Lossnay within
Group 2
a group is permitted by a
Lossnay remote controller.
Lossnay
( PZ-60DR-E or PZ-52SF-E )
• One group of a maximum
R1
of 16 Lossnay units can be
operated.
Group 4
• Number of Lossnay control
units
Lossnay Lossnay
Centralized controller
( AG-150A ) :
R1
50 units/50 groups
ON/OFF remote controller
( PAC-YT40ANRA ) :
50 units/16 groups
System remote controller
Group 2
( PAC-SF44SRA ) :
50 units/50 groups
Lossnay
*1: The remote controller
R2
*2: PZ-60DR-E and PZ-52SF-E
Group 4
Lossnay
Lossnay
R2
─ 15 ─
Features
used in this system.
cannot be used together.
( PZ-41SLB-E ) cannot be
used in this system.
can not be used together.
Prepared
Parts
• Lossnay
remote
controller
( PZ-60DR-E
or
PZ-52SF-E )
• Centralized
controllers
( G-50A ) ,
( PAC-
SF44SRA ) ,
( PAC-
YT40ANRA ) ,
and
( AG-150A )
• Power sup-
ply units
( PAC-
SC50KUA ) ,
( PAC-
SF46EPA ) ,
and ( PAC-
SC51KUA )