Ventilation - Miele KFNS 37432 iD Operating And Installation Instructions

Table of Contents

Advertisement

Risk of damage due to high
humidity.
In environments with high humidity,
condensation can build up on
external appliance panels, which can
cause corrosion.
Install the refrigeration appliance in a
dry and/or air-conditioned room with
sufficient ventilation.
After installation, make sure that the
appliance doors close properly, the
ventilation gaps are not covered and
that the appliance has been installed
in accordance with these operating
and installation instructions.
Climate range
The appliance is designed for use within
a certain climate range (ambient
temperatures) and should not be used
outside this range. The climate range of
the appliance is stated on the data plate
inside the appliance.
Climate range
SN
N
ST
T
Operating in a room which is too cold
will result in the compressor switching
off for too long, causing the internal
temperature in the appliance to rise with
the risk of food deteriorating and going
off.
Ambient room
temperature
+10 to +32 °C
+16 to +32 °C
+16 to +38 °C
+16 to +43 °C

Ventilation

If the required ventilation gaps
are not adhered to, the compressor
will switch on more often and run for
longer.
This will result in increased energy
consumption and a higher operating
temperature of the compressor. This,
in turn, may cause damage to the
compressor.
It is essential to observe the required
ventilation gaps.
Air at the back of the appliance gets
warm. The appliance housing unit must
therefore be constructed to allow
sufficient space for ventilation (see
"Building-in dimensions").
– Air intake  occurs via the plinth at
the bottom of the appliance and the
air escapes at the top  at the back
of the housing unit.
– A ventilation gap of at least 40 mm
depth must be allowed for behind the
appliance for air to circulate.
Installation
69