Huawei OptiX OSN 8800 Hardware Description page 88

Table of Contents

Advertisement

OptiX OSN 8800/6800/3800
Hardware Description
Valid Slots
One slot houses one fan tray assembly. The valid slot for the fan tray assembly is IU19.
Specifications of the Fan Tray Assembly
Table 4-56
subrack fan tray assembly.
Table 4-56 Technical specifications of the fan tray assembly
Item
Dimensions
Weight
Power Consumption
Life span
Issue 01 (2016-03-10)
lists the technical specifications of the OptiX OSN 8800 universal platform
For transport equipment, the heat consumption and power consumption are similar and can be
considered the same. Heat consumption is expressed in BTU/h and power consumption is expressed in
W. The conversion between the two units is as follows: 1 BTU/h = 0.2931 W.
Specification
442 mm (W) x 279 mm (D) x 47 mm (H) (17.40 in. (W) x 10.98
in. (D) x 1.85 in. (H))
3.4 kg (7.5 lb)
a
The average life span of a fan tray assembly varies depending on
the actual environment. Environments can be classified as
follows:
The average life spans of fan tray assemblies in different
environments are as follows:
NOTE
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Low Speed: 35 W
Medium-Low Speed: 43 W
Medium Speed: 68 W
Medium-High Speed: 134 W
High Speed: 190 W
Class A environment: refers to the indoor environment where
the ambient temperature and humidity are controlled
(including inhabited rooms).
Class B environment: refers to the indoor environment where
the ambient temperature and humidity are not controlled or the
common outdoor environment where only simple shelter (such
as awning) is available and the humidity occasionally reaches
100%.
Class A environment: 6.5 years
Class B environment: 5 years
The previous life spans are the average values concluded based on the test
data in a lab and the theoretical model, rather than the actual values. They
are for reference only. The actual life span must be determined based on
the environment conditions of a specific area. In addition, the previous life
spans do not indicate that a fan tray assembly becomes unavailable
immediately at the end of its life span. They are used to prompt users to
4 OptiX OSN 8800 Subrack